p.87JA4.1.2.4 Double Walls
p.87The U-factor of double walls or other double assemblies may be determined by combining the U-factors from the individual construction assemblies that make up the double wall. The following equation shall be used.
Equation text: 1 U = Combined 1 1 + U U 1 2
Needs visual review
p.87JA4.1.3 Tapered Insulation
p.87If continuous roof insulation is tapered for drainage or other purposes, then the user may determine the overall U-factor in one of two ways:
p.87(a) To determine the U-factor for the roof at the location where the insulation is at a
p.87minimum and where it is at a maximum. Take the average of these two U-factors. With the R-value compliance approach (prescriptive method only), calculate the R- value as the inverse of the average U-factor as determined above. R-values may not be averaged.
p.87(b) Divide the roof into sub-areas for each one-inch increment of insulation and
p.87determine the U-factor of each sub-area. This approach may only be used with the performance method, and in this case, each sub area shall be modeled as a separate surface.
p.87When roofs have a drain located near the center and when tapered insulation creates a slope to the drain, the surface area at the maximum insulation thickness will be significantly greater than the surface area at the minimum thickness, so the second method will give a more accurate result. The first method yields a conservative estimate for roofs with central drains.
p.87JA4.1.4 Insulating Layers on Mass and Other Walls
p.87The data in Table 4.3.14 may be used to modify the U-factors and C-factors from Table 4.3.5, Table 4.3.6, and Table 4.3.7 when an additional layer is added to the inside or outside of the mass wall. For exterior insulation finish systems (EIFS) or other insulation only systems, values should be selected from row 26 of Table 4.3.14 In these cases, the R-value of the layer is equal to the R-value of the insulation. The other choices from this table represent systems typically placed on the inside of mass walls. The following equations calculate the total U-factor or C-factor, where Umass and Cmass are selected from Table 4.3.5, Table 4.3.6, or Table 4.3.7 and ROutside and RInside are selected from Table 4.3.14. Routside is selected from row 26 while Rinside is selected from rows 1 through 25.
Equation text: 1 U = Total 1 R + + R Outside Inside UMass Equation 4-4
Needs visual review
p.87Appendix JA4 – U-factor, C-factor, and Thermal Mass Data