RA2.6.4.3 Corrective Action

p.3162025 Residential Appendices RA2.6.4.3 Corrective Action

p.316Builders shall offer to provide the necessary field verification and diagnostic testing services and any necessary corrective action at no charge to building owners (for a definition of “building owner” and of other terms used, see Reference Joint Appendix JA1) in occupied dwelling units in the group. Builders shall report to the ECC-Provider the identifying location of any dwelling unit in which the building owner or occupant declines field verification and diagnostic testing and corrective action. The ECC-Provider shall verify that the builder has made this offer. If a building owner of a dwelling unit declines this offer, field verification, diagnostic testing, and corrective action will not be required for that dwelling unit and the dwelling unit will no longer be considered a part of the group. If a building owner accepts this offer, the builder shall take corrective action, and the ECC-Rater shall conduct field verification and diagnostic testing to verify that problems have been corrected. Upon verification of compliance, the ECC-Rater shall transmit the test results to the ECC-Provider data registry. Whereupon the Provider shall make available to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry, a registered copy of the Certificate of Verification for the dwelling unit.

p.316The ECC-Provider shall file a report with the enforcement agency explaining all actions taken (including field verification, diagnostic testing, corrective action, offers to building owners for testing and corrective action, and/or building owner declines of such offers) to bring into compliance dwelling units for which full testing has been required. If corrective action requires work not specifically exempted by the CMC or the CBC, the builder shall obtain a permit from the enforcement agency prior to commencement of any of the work.

p.316Corrections to avoid reporting a failure to the ECC-Provider data registry shall not be made to a sampled dwelling unit after the ECC-Rater selects the sample dwelling unit. If it is evident that such corrections have been made to a sampled dwelling unit to avoid reporting a failure, field verification and diagnostic testing shall be required for 100 percent of the dwelling units in the group.

p.316RA2.7 Third Party Quality Control Programs

p.316The Energy Commission may approve Third Party Quality Control Programs (TPQCP) to verify the work of participating installers, collect and evaluate more detailed data than necessary for compliance, identify in real time during the installation invalid and inaccurate installer testing and noncompliant installations, and enable corrected testing with the goal of bringing installations into compliance before the installer leaves the job site. TPQCP personnel and participating TPQCP installation contractors do not have the authority to sign Certificate of Verification documentation as a ECC-Rater.

p.316RA2.7.1 Third Party Quality Control Program Responsibilities

p.316An approved Third Party Quality Control Program shall:

p.316a. Provide training to participating program installers (including contractors, subcontractors,

p.316and technicians) to ensure proficiency in:

p.316Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Procedures