JA8.3.1 Luminous Efficacy Test

p.232JA8.1 Purpose and Scope

p.232Joint Appendix JA8 provides the qualification requirements for high luminous efficacy light sources installed to comply with Section 150.0(k). For the purposes of this Section, high luminous efficacy light sources include ballasts or LED drivers if needed for operation of the light source: light sources shall be certified together with a driver or ballast. If the light source is inseparable from the luminaire the entire luminaire shall meet the requirements of this section. All qualifying light sources shall be certified to the Energy Commission according to all of the requirements in this Appendix.

p.232JA8.2 Certification of Test Labs

p.232The light source under test shall be tested at a testing laboratory accredited to ISO/IEC 17025:2017, by the National Voluntary Laboratory Accreditation Program (NVLAP) or other laboratory accreditation body operating in accordance with ISO/IEC 17011 and produced under an ongoing inspection program carried out by a Type A inspection body in accordance with ISO/IEC 17020.

p.232JA8.3 Tests to be performed

p.232Compliance with the requirements of this Appendix shall be determined by performance of the following test procedures, as applicable to the type of light source.

p.232Sample group size shall be as specified in the referenced test procedures. Where a sample group is not specified for a test, a single unit shall be tested.

p.232JA8.3.1 Luminous Efficacy Test

p.232For federally regulated light sources, luminous efficacy shall be determined by the test procedures specified in 10 CFR 429 Subpart B and 10 CFR 430.23(gg).

p.232For non-federally regulated light sources, luminous efficacy at full light output shall be determined by the following test procedures, as applicable to the type of light source:

p.232a) For LED light sources, IES LM-79. b) For high intensity discharge lamps, IES LM-51. c) For induction lamps, IES LM-66. The reported value shall be the minimum luminous efficacy of the tested units and be rounded to the nearest tenth.

p.232JA8.3.2 Power Factor Test

p.232Power factor shall be measured at full light output in accordance with ANSI C82.77, Section 6 and 7.

p.232For lamps, the reported value shall be the average measured values of the tested units rounded to be the nearest tenth.

p.232For all other sources, the reported value shall be the minimum power factor of the tested units rounded to the nearest tenth.

p.232Appendix JA8 – Qualification Requirements for High Luminous Efficacy Light Sources