p.2662025 Joint Appendices
p.266JA13.1 Purpose and Scope Joint Appendix JA13 provides the qualification requirements for a heat pump water heater (HPWH) demand management system (System) to meet the requirements for HPWH demand flexibility compliance credit available in the performance standards specified in Title 24, Part 6, Sections 150.1(b).
p.266User interfaces referenced in these requirements shall be designed for use by a typical residential user.
p.266JA13.2 Definitions
p.266Heat Pump Water Heater Demand Management System
p.266The HPWH Demand Management System means the following components connected to a water heater, but not the water heater itself, all of which are necessary to fulfill the primary function of the System:
p.266(a) Any hardware or software contained inside the water heater;
p.266(b) Any hardware or software installed on premise (including a module); and
p.266(c) Any software contained in applications or in the cloud.
p.266The primary function of the System is to interface with the HPWH to serve the users’ domestic hot water needs and provide daily load shifting, as applicable, for the purpose of user bill reductions, maximized solar self-utilization, and grid harmonization.
p.266Local and Remote Methods
p.266A Local Method means a method that can be performed from within the building that does not require the System to have a live connection to an off-premise source. A temporary connection to a live off-premise source such as via a smart phone, may be used for local setup and updates.
p.266A Remote Method means a method that is performed via a live connection to an off- premise source, such as the internet, advanced metering infrastructure (AMI), or cellular communication.
p.266JA13.3 Qualification Requirements To qualify for the HPWH Demand Management System performance compliance credit, the System shall be certified to the Energy Commission to meet the following requirements:
p.266Safety Requirements The System shall comply with applicable installation standards in the California electrical, mechanical, and plumbing codes.
p.266A thermostatic mixing valve conforming to ASSE 1017 shall be installed on the hot water supply line following all manufacturer installation instructions or the water heater shall
p.266Appendix JA13 – Qualification Requirements for Heat Pump Water Heater Demand Management System