p.234Minimum dimming level is measured by comparing the stabilized light output of the light source with the dimming control set to full light output with the dimming control being set to the manufacturer’s minimum rated output. Full light output and minimum light output is measured after the light output has stabilized according to the test procedures specific to light source type in Section JA 8.3.1.
p.234In addition to the reporting of flicker results as described in Section JA8.6, flicker test data for each combination of light source, ballast or driver (if applicable), transformer type and dimmer type claiming compliance with JA8 shall be submitted to the California Energy Commission.
p.234Testing for minimum dimming level, flicker, and audible noise is required for each combination of light source, ballast or driver (if applicable), transformer type and dimmer type as follows:
p.234a) Low voltage light sources shall be tested with a representative transformer for
p.234each transformer type that the light source is claiming compatibility.
p.234b) Light sources claimed as compatible with forward phase-cut dimmers shall be
p.234tested in combination with a NEMA SSL 7A compliant dimmer.
p.234c) Light sources claimed as compatible with dimmers other than forward phase-cut
p.234dimmers, dimmability, low noise and low flicker operation shall be tested for each ballast or driver combination (if applicable) with at least one representative dimmer for each dimmer type for which compatibility is claimed.
p.234JA8.4 Qualification Requirements
p.234The following qualification requirements must be met for the light source to be considered High Luminous Efficacy as specified in Section 150(k).
p.234JA8.4.1 Luminous Efficacy
p.234The light source shall meet the following requirements when measured in accordance with the test method of Section JA8.3.1:
p.234The luminous efficacy of the light source shall be equal to or greater than either the applicable State or federal appliance efficiency standard or 45 lumens/Watt, whichever is higher, when tested at its full light output.
p.234JA8.4.2 Power Factor
p.234The light source shall meet the following requirements when measured in accordance with the test method of Section JA8.3.2:
p.234The light source shall have a power factor equal to or greater than 0.90 when tested at its full light output.
p.234JA8.4.3 Start Time
p.234The light source shall meet the following requirements when measured in accordance with the test method of Section JA8.3.3:
p.234Appendix JA8 – Qualification Requirements for High Luminous Efficacy Light Sources