JA8.7.1 Definitions

p.239JA8.7 Start Time Test Method

p.239JA8.7.1 Definitions

p.239Device Under Test (DUT): the integrated LED lamp, LED light engine, or LED luminaire which is undergoing the start time test.

p.239Start Time: the time between the application of power to the DUT and the point where the light source is continuously illuminated, and the light output is either constant or increasing. DUTs with integral controls (e.g., motion sensors, photosensors, wireless control, standby mode, or connected functionality) may have these controls disabled or bypassed for this testing.

p.239Initial Plateau: the point at which the average increase in the light output over time levels out (reduces in slope). This can be determined mathematically or visually based on the output trace.

p.239JA8.7.2 Methods Of Measurement and Reference Documents

p.239IES LM-79.

p.239JA8.7.3 Test Setup

p.239A. Test Setup and Instrumentation:

p.2391. Regulated AC or DC power supply (as applicable to the DUT)

p.2392. Multichannel oscilloscope with data storage capability

p.2393. Appropriate attenuator probes

p.2394. Photodetector

p.239B. Seasoning and Preburning: SSL sources shall not be seasoned.

p.239C. Input Power for Start Time Measurements: The power requirements shall be per IES

p.239LM-79 as applicable. When selecting a power supply for use with integrated lamps and luminaires, it is necessary to apply an appropriate power factor when specifying the Volt-Amp capacity of the power supply.

p.239D. Storage: Lamps and luminaires shall be stored at 25°C ± 5°C for a minimum of 16

p.239hours prior to the test, after which the temperature range shall be 25°C ± 1°C for at least two hours immediately prior to the test.

p.239E. Ambient Temperature: Testing shall take place in an ambient temperature of 25°C ±

p.2391°C. Drafts shall be minimized.

p.239F. Power Meter: Power meters shall be capable of measuring to the appropriate

p.239requirements of IES LM-79 as applicable.

p.239G. Environmental Conditions: The test environment shall be clean and free from large

p.239amounts of dust and moisture.

p.239H. Orientation: Test samples in orientation(s) as specified by the ENERGY STAR

p.239specification or manufacturer specified position if different.

p.239Appendix JA8 – Qualification Requirements for High Luminous Efficacy Light Sources