JA8.7.4 Test Conduct

p.240I. Sample Selection: Samples shall be representative of the manufacturer’s typical

p.240product. The samples shall be clean and thoroughly inspected before testing. Any flaws or inconsistencies in the DUT samples shall be noted.

p.240JA8.7.4 Test Conduct

p.240Photometric Measurements:

p.240A. For integrating sphere measurements, refer to IES-LM-79 as applicable.

p.240B. For non-integrating sphere measurements, the photodetector used for photometric

p.240measurements shall be a silicon detector corrected to closely fit the Commission Internationale de l’Eclairage (CIE) spectral luminous efficiency curve (Vil).

p.240JA8.7.5 Test Procedure

p.240A. Install the DUT in the test environment. The driver may be external to the test

p.240environment, if applicable.

p.240B. For non-integrating sphere measurements, position the photocell so it sees the main

p.240body of the discharge tube or array (as applicable). Shield from extraneous light as needed. C. For integrating sphere measurements, see test conduct section JA8.7.4.

p.240D. When testing DUTs with sensors (e.g. motion sensors, photosensors) the sensors

p.240may be disabled or bypassed for this testing.

p.240E. Connect oscilloscope probe to measure the input voltage to the sample, and light

p.240output.

p.240F. Set the scope to trigger off the input voltage signal. Set trigger level at 10V.

p.240G. Set power supply to rated voltage and frequency of the DUT. If a range is specified,

p.240test sample at the midpoint of the range.

p.240H. Use an exemplar sample to determine the proper voltage and time base settings.

p.240Suggested initial time base is 200 ms/div.

p.240I. Apply rated voltage/frequency to the DUT.

p.240J. Record the input voltage and light output waveform on which the starting time was

p.240based.

p.240K. Record Start Time.

p.240Appendix JA8 – Qualification Requirements for High Luminous Efficacy Light Sources