| Measure Title | Description | Procedure(s) | |||
|---|---|---|---|---|---|
| Verified Drain Water Heat Recovery System (DWHR-H) | Inspection to verify that the DWHR unit(s) and installation configuration match the compliance document and the DWHR(s) is certified to the Commission to have met the requirements. | RA3.6,9 | |||
| Table RA2-7 – Summary (Continued) Multi Family Domestic | of Hot | Measures Requiring Field Verification and Diagnostic Testing Water Heating Measures | |||
| Measure Title | Description | Procedure(s) | |||
| Central Verified Pipe Insulation for Systems | Inspection to verify that the central system hot water piping, fittings and appurtenances are continuously insulated per mandatory requirements. | RA3.6.3 | |||
| H) Verified Drain Water Heat Recovery System (DWHR | Inspection to verify that the DWHR unit(s) and installation configuration match the compliance document and the DWHR(s) is certified to the Commission to have met the requirements. | RA3.6.9 | |||
| 1. Note: Compliance credit verification if the R-value is where all registers are either enforcement agency inspection. 2. Note: The requirement for for the in increased duct insulation R-value (not buried ducts) may be taken without same throughout the building, and for ducts located in crawlspaces and the floor or within 2 feet of the floor. These two credits may be taken verification of a high EER2 does not apply to equipment rated only with an | field garages subject only to EER2. | ||||
p.300RA2.3 Documentation and Communication Requirements for Verification Compliance
p.300The building energy compliance features, field verification requirements, and applicable special feature eligibility criteria shall be identified on a Certificate of Compliance that conforms to the requirements in Standards Sections 10-103(a)1 and 10-103(a)2. The builder or subcontractor shall submit all applicable Certificate of Installation documentation in conformance with the requirements in Standards Section 10-103(a)3 and the procedures described in RA2, and shall provide certification that the construction/installation complies with all applicable requirements on the Certificate of Compliance and complies with all applicable field verification and eligibility criteria. Field verification shall be performed by an ECC-Rater and documented on applicable Certificate of Verification documentation that conforms to the requirements of Standards Section 10-103(a)5 and the procedures in RA2.
p.300RA2.3.1 Documentation Constraints, Registration, and Verification
p.300The performance compliance method allows for preparation of Certificate of Compliance documentation for multifamily buildings that precludes use of certain verification compliance credits that would otherwise be available for compliance credit as described in Section RA2.3.1.1 below. Document registration is required for all dwelling units that utilize building energy features for which verification is required as introduced in Section RA2.3.1.2 and described in the
p.300Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Procedures