RA2.3.1.1 Whole-Building Compliance Approach for Multifamily Buildings

p.3012025 Residential Appendices procedures in subsequent sections of RA2. Verification of electronic documentation is introduced in section RA2.3.1.3 and is applicable to many aspects of the documentation procedures described in subsequent sections of RA2.

p.301RA2.3.1.1 Whole-Building Compliance Approach for Multifamily Buildings

p.301For multifamily buildings, a single Certificate of Compliance may be prepared for the whole building, however dwelling unit-specific Certificates of Installation and dwelling unit-specific Certificates of Verification shall be required for each individual dwelling unit in the building. Thus, for the whole-building compliance approach in a multifamily building utilizing features that require verification, the required energy compliance documentation for each dwelling unit shall consist of a copy of the whole-building Certificate of Compliance, the applicable dwelling unit- specific Certificates of Installation, and the applicable dwelling unit-specific Certificates of Verification.

p.301When the whole-building compliance approach is utilized for a multifamily building, some energy efficiency measures that require field verification shall not be used for compliance credit in performance compliance calculations. These measures require dwelling unit-specific information input to the compliance software, and dwelling unit-specific information that must be shown on the Certificate of Compliance, thus these measures cannot be properly documented using a whole-building Certificate of Compliance (which is not a dwelling unit-specific document type). The measures that shall not be utilized for the multifamily whole-building compliance approach are:

p.301(a) Buried Ducts credit

p.301(b) Deeply Buried Ducts credit

p.301(c) Reduced Duct Surface Area credit

p.301(d) Building Envelope Sealing credit for reduced outdoor air infiltration (blower door test)

p.301All other measures that require field verification and diagnostic testing are allowed for use with the multifamily whole-building compliance approach.

p.301RA2.3.1.2 Document Registration

p.301For all low-rise residential buildings for which compliance requires field verification, all Registered Compliance Document and Compliance Registration Package (Certificate of Compliance, Certificate of Installation, and Certificate of Verification) required for the dwelling unit shall be submitted for registration and retention to an ECC-Provider data registry. When submittal of documentation to an ECC-Provider data registry is required, the completed documents are referred to as registered documents, and the process of completing these documents by submitting information (Compliance Registration Package) and certification signatures to the ECC-Provider data registry is called registration. Refer to Reference Joint Appendix JA1 for the definitions for ECC-Provider data registry, and for registered document. Additional specification for the document registration process is given in Reference Joint Appendix JA7.

p.301Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Procedures