JA8.8.1 Definitions

p.241JA8.8 Noise Test Method

p.241JA8.8.1 Definitions

p.241Unit Under Test: The unit under test (UUT) refers the specific lamp sample being tested.

p.241Baseline Light Output: The baseline light output (BLO) refers to the stabilized light output of the unit under test (UUT) is operating without a dimmer in the circuit.

p.241Maximum Control Position: The setting on the dimmer or control device intended to achieve the maximum light output during operation.

p.241Maximum Light Output: The maximum light output (MaxLO) refers to the light output of the UUT when operating with a dimmer in the circuit at the Maximum Control Position.

p.241Minimum Dimming Level Claimed: The minimum light output level of a UUT when operated with a dimmer in the circuit, as declared by the lamp manufacturer. Typically expressed as a percentage.

p.241Minimum Light Output: The minimum light output (MinLO) refers to the minimum light output when the UUT is operating with a dimmer in the circuit.

p.241Peak Noise: The highest time-averaged sound value recorded at a measurement point during stable operation of the UUT.

p.241JA8.8.2 Methods Of Measurement and Reference Documents

p.241A. IES LM-79.

p.241B. ISO 7574-4 B.2.1: 1985. Statistical methods for determining and verifying stated

p.241noise emission values of machinery and equipment, International Organization for Standardization, Geneva, Swizerland.

p.241C. ASA S12.55-2006/ISO3745:2003: 2006. Acoustical Society of America, New

p.241York.

p.241JA8.8.3 Recommended Practice Test Setup

p.241A. Test Setup and Instrumentation: The test can be performed using a single microphone

p.241and rotating the product, or by using multiple microphones. Equipment required for measurement is as follows:

p.2411. Regulated AC or DC power supply (as applicable to the UUT or transformer).

p.2412. Multichannel oscilloscope with data storage capability or similar equipment for comparing output readings from a photodetector.

p.2413. Appropriate attenuator probe(s), if applicable.

p.2414. Photodetector capable of measuring relative light output.

p.2415. Noise level measurement equipment.

p.2416. Microphone(s).

p.2417. Isolated sound chamber (e.g., anechoic chamber).

p.241B. Lamp Seasoning and Preburning: LED lamps shall not be seasoned.

p.241Appendix JA8 – Qualification Requirements for High Luminous Efficacy Light Sources