JA8.8.4 Test Conduct - Guidance for Noise Test Procedure

p.242C. Input Power for Measurements: The power requirements shall be per IES LM-79 as

p.242applicable. Note: When selecting a power supply, it is necessary to apply an appropriate power factor when specifying the Volt-Amp rating of the power supply.

p.242D. Ambient Temperature: testing of the UUT shall take place in an ambient temperature

p.242of 25°C ± 5°C. Drafts shall be minimized.

p.242E. Power Meter: Power meters shall be capable of measuring to the appropriate

p.242requirements of IES LM-79 as applicable.

p.242F. Environmental Conditions: The test environment shall be clean and free from large

p.242amounts of dust and moisture.

p.242G. Sample Selection: Samples shall be representative of the manufacturer’s typical

p.242product. The samples shall be clean and thoroughly inspected before testing. Any flaws or inconsistencies in the samples shall be noted. The samples used for noise testing shall be the same sample(s) used for testing for meeting Joint Appendix JA10, if applicable, and can be the same sample(s) used for other testing.

p.242JA8.8.4 Test Conduct - Guidance for Noise Test Procedure

p.242A. Photometric Measurements:

p.2421. For absolute measurements, refer to IES LM-79 as applicable with the exception of the guidance for stabilization.

p.2422. The photodetector used for photometric measurements shall be a silicon detector corrected to closely fit the Commission Internationale de l’Eclairage (CIE) spectral luminous efficiency curve (Vil).

p.242Ensure that the measurement equipment receives the appropriate voltage range from the photodetector, using an amplifier if necessary.

p.242B. Measurement Equipment:

p.2421. The sound chamber shall provide an environment suitable for the sound testing of the UUT. External sources of noise shall be minimized.

p.2422. The sound measurement equipment shall be capable of measuring A-weighted decibels.

p.2423. The microphone(s) shall be placed at a distance of one (1) meter or less from the UUT to be measured.

p.242i) If multiple microphones are used, 6 microphones shall be placed about the

p.242UUT spaced 90° apart and aimed at the UUT.

p.242ii) If a single microphone is used, the microphone shall be aimed at the UUT and

p.242the UUT holding device shall be capable of moving and holding the UUT so that six measurements about the UUT can be made 90° apart.

p.2424. The sound level of the UUT shall be calculated from the measurement taken.

p.242i) The baseline level may be corrected for in accordance with ISO 7574-4:1985,

p.242B.2.1.

p.242Appendix JA8 – Qualification Requirements for High Luminous Efficacy Light Sources