p.4182025 Residential Appendices RA3.5.7.4.1 Homes with Floors Over Garage
p.418On floors that are over garages, the rim joist shall be insulated.
p.418RA3.5.7.4.2 Homes with Conditioned Space Over Garage
p.418The separation between conditioned space (house) and the garage shall be insulated to create a continuous thermal barrier. All rim and band joists adjoining conditioned space shall be airtight and insulated.
p.418Figure RA3.5-9 Homes with Conditioned Space Over Garage – Structural Insulated Panel (SIP)
p.418RA3.5.7.4.3 Homes with No Conditioned Space Over Garage
p.418The band joist where the garage transitions to an attic above conditioned space shall have an air barrier installed in contact with the edge of the attic insulation.
p.418Figure RA3.5-10 Homes with No Conditioned Space Over Garage – Structural Insulated Panel (SIP)
p.418– Residential Field Verification and Diagnostic Test Protocols