RA2.6.4.1 Re-sampling procedures for a “closed” group of up to seven dwellings:

p.3142025 Residential Appendices subject to verification and testing under the supervision of a previous ECC-Provider, for which the builder does not have a completed Certificate of Verification, shall be individually tested, or included in a separate group for sampling. Dwelling units with installations completed by new subcontractors shall be individually tested or shall be included in a new sampling group.

p.314The ECC-Rater shall not notify the builder when sample testing will occur prior to the completion of the work that is to be tested, or prior to registration of the Certificate of Installation.

p.314The ECC-Provider shall “close” any “open” group within 6 months after the earliest signature date shown on any Certificate of Installation for a dwelling entered in the group. When such group closure occurs, the ECC-Provider shall notify the builder that the group has been “closed” and require that a sample dwelling shall be selected for field verification and diagnostic testing by a ECC-Rater if field verification has not yet been conducted on a sample dwelling entered in the group.

p.314RA2.6.4 ECC-Rater Procedures - Re-sampling, Full Testing and Corrective Action

p.314“Re-sampling” refers to the procedure that requires testing of additional dwellings within a group when the initial selected sample dwelling from a group fails to comply with the verification requirements.

p.314When a failure is encountered during sample testing, the failure shall be entered into the ECC- Provider data registry. Corrective action shall be taken on the failed dwelling unit and the dwelling unit shall be retested to verify that corrective action was successful. Corrective action and retesting on the dwelling unit shall be repeated until the testing indicates compliance and the successful compliance results have been entered into the ECC-Provider data registry (or the dwelling unit complies using an alternative method). Whereupon a registered Certificate of Verification for the dwelling shall be made available to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry.

p.314In addition, the ECC-Rater shall conduct re-sampling to assess whether the first failure in the group is unique, or if the rest of the dwelling units in the group are likely to have similar failings.

p.314RA2.6.4.1 Re-sampling procedures for a “closed” group of up to seven dwellings:

p.314The ECC-Rater shall randomly select for re-sampling one of the remaining untested dwelling units in the group for retesting of the feature that failed. If the failed dwelling was entered in a “closed” group, and the testing of the second randomly selected dwelling unit in the group confirms that the requirements for compliance credit are met on that unit, then the dwelling unit with the initial failure shall not be considered an indication of failure in the remaining untested dwelling units in the group. The ECC-Rater shall transmit the re-sample test results to the ECC- Provider registry, whereupon the Provider shall make available to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry, a registered copy of the Certificate of Verification for the remaining dwelling units in the group including the dwelling unit in the re-sample.

p.314If field verification and diagnostic testing of the second sample results in a failure, the ECC-Rater shall report the second failure to the ECC-Provider, the builder, and the enforcement agency. All dwelling units in the group must thereafter be individually field verified and diagnostically tested

p.314Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Procedures