p.3112025 Residential Appendices group. If some dwelling units have installed a different set of measures requiring verification, those dwelling units shall be in a separate group.
p.311If the dwelling units in a designated group have multiple measures that require verification, sample testing for individual measures may be conducted in any of the dwelling units in the group - it is not required that all of the sample tests for all of the individual measures be completed in the same dwelling unit. Individual measures shall be allowed to be included in a group regardless of whether compliance requires one sample test, or if compliance requires more than one sample test (up to100% sample test rate) be reported for such individual measures.
p.311Dwelling units in a designated group shall all be located within the same enforcement agency jurisdiction and subdivision or multifamily housing development. Refer also to Section RA2.8 for requirements for sample groups applicable to alterations.
p.311If dwelling units have central forced-air space conditioning equipment that introduces outside air into the conditioned space utilizing means that connect outside air ventilation ducts directly to the dwelling unit’s central forced air duct system (Central Fan-Integrated Ventilation System or CFI Ventilation System), the CFI ventilation technology shall be considered a separate measure for verification sampling purposes, and dwellings with CFI ventilation systems shall be placed in separate groups from other dwelling units that do not utilize CFI ventilation technology.
p.311RA2.6.3.2 Group Status - "Open" Groups and "Closed" Groups
p.311Registration of the first Certificate of Installation, for the first dwelling in a sample group shall be required to “open” a new group. The date of the responsible persons registration signature for the first Certificate of Installation for the group shall establish the start date for the group. Additional dwellings may be entered into the registry and included in an “open” group over a period of time subject to registration of the Certificate of Installation documents for each additional dwelling. However, the group shall not remain “open” to receive additional dwellings for a period longer than six months after the start date of the group. A group may be “closed” at any time after the group has been “opened” at the option of the builder or builder’s authorized representative, thus the size of a “closed” group may range from a minimum of one dwelling to a maximum of seven dwellings. When a group becomes classified as “closed”, no additional dwellings shall be added to the group.
p.311RA2.6.3.3 Sampling of a “Closed” Group of Up to Seven Dwellings
p.311The following criteria shall be met as prerequisite to attaining verification compliance for the group:
p.311(a) All of the dwelling units contained in the sample group have been identified. A maximum
p.311of seven dwellings are allowed to be included in a “closed” sample group for compliance.
p.311(b) Installation of all the measures that require verification has been completed in all the
p.311dwellings that are entered in the group, and registration of the Certificates of Installation for all the dwellings entered in the group has been completed.
p.311(c) The group has been classified as a “closed” group in the Provider data registry.
p.311Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Procedures