RA2.6.3.1 Designation of Groups

p.3102025 Residential Appendices The Certificate of Verification shall be signed by the ECC-Rater who performed the field verification and diagnostic testing services to certify that the information provided on the Certificate is true and correct.

p.310A completed signed registered copy of the Certificate of Verification shall be posted at the building site for review by the enforcement agency in conjunction with requests for final inspection for each dwelling unit. Alternatively, the enforcement agency may elect to view the certificates on an approved Data Registry.

p.310The ECC-Provider shall make document verification services available, to enforcement agencies, builders and contractors, ECC-Raters, the Energy Commission, and other authorized users of the ECC-Provider data registry.

p.310RA2.6.2 ECC-Rater Procedures - Initial Model Field Verification and Diagnostic Testing

p.310The ECC-Rater shall diagnostically test and field verify the first dwelling unit of each model within a subdivision or multifamily housing development when the builder elects to demonstrate verification compliance utilizing group sampling. To be considered the same model, dwelling units shall have the same basic floor plan layout, energy design, and compliance features as shown on the Certificate of Compliance. Variations in the basic floor plan layout, energy design, compliance features, zone floor area, or zone volume, that do not change the features to be tested, the heating or cooling capacity of the HVAC unit(s), or the number of HVAC units specified for the dwelling units, shall not cause dwelling units to be considered a different model. For multifamily buildings, variations in exterior surface areas caused by location of dwelling units within the building shall not cause dwelling units to be considered a different model. This initial model testing allows the builder to identify and correct any potential construction flaws or practices in advance of the build out of each model. If field verification and diagnostic testing determines that the requirements for compliance are met, the ECC-Rater shall transmit the test results to the ECC-Provider data registry, whereupon the Provider shall make available a registered copy of the Certificate of Verification, to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry.

p.310RA2.6.3 ECC-Rater Procedures – Group Sample Field Verification and Diagnostic Testing

p.310Descriptions for verification compliance using group sampling, and details describing procedures for sampling of a “closed” group of up to seven dwellings, and for sampling of an “open” group of up to five dwellings are described in Section RA2.6.3.

p.310RA2.6.3.1 Designation of Groups

p.310After the initial model field verification and diagnostic testing is completed as specified in RA2.6.2, the builder, or the builder’s authorized representative shall determine a sampling procedure to be used and shall designate the dwelling units to include in the group of dwellings that require verification. The maximum number of dwelling units allowed in a sample group may range from five, to seven, to thirty as described in Sections RA2.6.3.3, RA2.6.3.4, and RA2.7 respectively.

p.310If multiple measures requiring verification are installed, each dwelling unit in a designated group shall have the same measures requiring verification as the other dwelling units in the designated

p.310Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Procedures