p.4472025 Residential Appendices (g) A copy shall be given to the building owner and the enforcement agency for their records.
p.447RA4.2.2.2 Window Film
p.447These procedures detail the installation protocols necessary for window films. Each window film product to be installed is provided with a temporary NFRC Label on the box to identify the thermal performance efficiencies (e.g., U-factor, Solar Heat Gain Coefficient (SHGC), and Visible Transmittance (VT)). The labels shall be located at the job site for verification by the enforcement agency. In addition, the responsible person or the installer shall fill out the Installation Certificate and shall verify the thermal performance efficiencies of each window film to be installed matches the energy Certificate of Compliance documentation and the building plans orientation schedule. A copy of the Installation Certificates shall be given to the building owner and the enforcement agency for their records along with other window film information.
p.447RA4.2.2.2.1 Window Film Documentation at Occupancy
p.447(a) The IWFA Architectural Visual Inspection Standard Window Film (dated August 21, 2018), a
p.447copy can be obtained through www.iwfa.com;
p.447(b) A sample (8” x 10”) of the film installed with a copy of its Performance Specification Sheet
p.447attached; and
p.447(c) A 15 or more year Warranty Certificate(s) shall be given to the building owner.
p.447RA4.2.2.3 The Responsible Person or Installer Shall Verify Before Installation;
p.447(a) Name of the manufacture, brand name, model matches building plans or energy compliance
p.447forms; and
p.447(b) From the building plans or energy compliance documentation identify the azimuth
p.447orientation in degrees or in cardinal orientation for each of the window film to be installed to ensure the correct window film type is installed in the appropriate orientation; and
p.447(c) Verify the temporary NFRC label on the box for each window film’s U-factor, Solar Heat Gain
p.447(SHGC) and Visible Transmittance (VT) matches the energy compliance documentation and building plans; and
p.447(d) List the NFRC Certified Product Directory (CPD) identification number provided on the label
p.447on the Installation Certificate form; and
p.447(e) If no NFRC Label is included on the box or identification of the window film, then verify with
p.447the Responsible Person of the building construction or enforcement agency to ensure the window film used actually meets or exceeds the energy specifications; and
p.447(f) Installation of window films shall follow the International Window Film Association (IWFA)
p.447Architectural Visual Inspection Standards Window Film (dated August 21, 2018); and
p.447(g) After the installation, the installer completes and signs the Declaration Statement on the
p.447Installation Certificate.
p.447– Eligibility Criteria for Energy Efficiency Measures