p.4432025 Residential Appendices When measuring watt draw of units that are wired directly to an electrical junction box, it is recommended to use portable true power clamp-on meters to provide flexibility for isolating the correct fan wires.
p.4442025 Residential Appendices (a) The measured WHF airflow (cfm) shall meet or exceed the WHF airflow compliance
p.444criterion specified on the Certificate of Compliance.
p.444(b) The calculated value for fan efficacy (watt/cfm) shall be less than or equal to the WHF
p.444efficacy compliance criterion specified on the Certificate of Compliance.
p.443RA3.9.4.2.2 WHF Watt Draw Measurement Using Utility Revenue Meter
p.443The WHF watt draw measurement shall be performed using the following procedures.
p.443(a) Turn off every circuit breaker except the one exclusively serving the WHF(s).
p.443(b) The WHF(s) shall be operating at the WHF-OP used for the airflow rate measurement
p.443procedures specified in Section RA3.9.4.1.
p.443(c) Record the Kh factor on the revenue meter, count the number of full revolutions of the
p.443meter wheel over a period exceeding 90 seconds.
p.443(d) Record the number of revolutions (Nrev) and time period (trev, seconds).
p.443(e) Using the following equation, compute the WHF watt draw (Wfan).
p.443Equation RA3.9-1 WHF Fan Watt Draw Wfan = (Kh x Nrev x 3600) / trev
p.443(f) Return all circuit breakers to their original positions.
p.443RA3.9.4.2.3 WHF Watt Draw Measurement Using Digital Utility Revenue Meter
p.443The WHF watt draw measurement shall be performed using the following procedures:
p.443(a) Turn off every circuit breaker except the one exclusively serving the WHF(s).
p.443(b) The WHF(s) shall be operating at the WHF-OP used for the airflow rate measurement
p.443procedures specified in Section RA3.9.4.1.
p.443(c) Read the Watt draw from the digital utility meter digital display.
p.443(d) Return all circuit breakers to their original positions.
p.443RA3.9.4.3 Determination of WHF Efficacy Demonstrating compliance with WHF efficacy requirements requires simultaneous measurement of the WHF airflow rate using Section RA3.9.4.1 procedures and fan watt draw using Section RA3.9.4.2 procedures. The results of the simultaneous airflow rate and fan Watt draw measurements are used for calculation of a value for the WHF efficacy as follows:
p.443RA3.9.4.3.1 Fan Efficacy Calculation (watt/cfm)
p.443The measured value for fan watt draw (watt) shall be divided by the measured value for airflow rate (cfm) to determine the fan efficacy (watt/cfm).
p.443RA3.9.4.4 WHF Compliance Criteria
p.443In order for the WHF to comply, the requirements in both subsections (a) and (b) below shall be met.
p.443Appendix RA3– Residential Field Verification and Diagnostic Test Protocolsp.444
p.444– Residential Field Verification and Diagnostic Test Protocols