p.3622025 Residential Appendices shall be fixed to the supply plenum at the location specified in Section RA3.3.1.1 so that it is not moved during this test.
p.362RA3.3.2.1.3 Powered Flow Capture Hood
p.362A powered and pressure balanced flow capture hood (subsequently referred to as a Powered Flow Hood1) that has the capability to balance the flow capture static pressure difference between the room and the flow capture hood enclosure to 0.0 ± 0.2 Pa (.0008 inches water) and meets the applicable instrumentation specifications in Section RA3.3.1 may be used to verify the system airflow rate at the return grille(s) if the powered flow hood has a flow capture area at least as large as the return grille in all dimensions. The fan adjustment needed to balance the flow capture static pressure difference between the room and the flow capture hood enclosure to 0.0 ± 0.2 Pa (.0008 inches water) shall be provided by either an automatic control or a manual control operated in accordance with the apparatus manufacturer's instructions specified in the manufacturer's product documentation. All supply registers shall be in their normal operating position. Measurement(s) shall be taken at the return grille(s).
p.362RA3.3.2.1.4 Traditional Flow Capture Hood
p.362A traditional flow capture hood2 meeting the applicable instrumentation specifications in Section RA3.3.1 may be used to verify the system airflow rate at the return grille(s) if the device has a capture area at least as large as the return grille in all dimensions. All registers shall be in their normal operating position. Measurement(s) shall be taken at the return grille(s).
p.362RA3.3.2.2 Air Handler Watt Draw Measurement Apparatus
p.362The air handler watt draw shall be measured using one of the following apparatuses.
p.362RA3.3.2.2.1 Portable Watt Meter
p.362The apparatus for measuring the air handler watt draw shall consist of a wattmeter meeting the applicable instrumentation specifications in RA3.3.1. The measuring device shall be attached to measure the air handler fan watt draw. All registers and blower access panel(s) shall be in their normal operating condition.
p.362When required to measure fan watt draw in packaged and heat pump units, it is recommended to use portable true power clamp-on meters to provide flexibility for isolating the correct fan wires serving in packaged or heat pump units. Note: Higher voltage clamp-on meters may be required for packaged and heat pump units.
p.362RA3.3.2.2.2 Utility Revenue Meter
p.362The apparatus for measuring the air handler watt draw shall consist of the utility revenue meter meeting the applicable instrumentation specifications in RA3.3.1 and a stopwatch that provides measurements in units of seconds. All registers and blower access panel(s) shall be in their normal operating condition.
p.3621 Also known as "active" flow hood, or "fan assisted" flow hood.
p.3622 Also known as "non-powered" flow hood, "standard" flow hood, "commercially available" flow hood, or "passive" flow hood.