p.314RA2.6.4 ECC-Rater Procedures - Re-sampling, Full Testing and Corrective Action
p.314“Re-sampling” refers to the procedure that requires testing of additional dwellings within a group when the initial selected sample dwelling from a group fails to comply with the verification requirements.
p.314When a failure is encountered during sample testing, the failure shall be entered into the ECC- Provider data registry. Corrective action shall be taken on the failed dwelling unit and the dwelling unit shall be retested to verify that corrective action was successful. Corrective action and retesting on the dwelling unit shall be repeated until the testing indicates compliance and the successful compliance results have been entered into the ECC-Provider data registry (or the dwelling unit complies using an alternative method). Whereupon a registered Certificate of Verification for the dwelling shall be made available to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry.
p.314In addition, the ECC-Rater shall conduct re-sampling to assess whether the first failure in the group is unique, or if the rest of the dwelling units in the group are likely to have similar failings.
p.314RA2.6.4.1 Re-sampling procedures for a “closed” group of up to seven dwellings:
p.314The ECC-Rater shall randomly select for re-sampling one of the remaining untested dwelling units in the group for retesting of the feature that failed. If the failed dwelling was entered in a “closed” group, and the testing of the second randomly selected dwelling unit in the group confirms that the requirements for compliance credit are met on that unit, then the dwelling unit with the initial failure shall not be considered an indication of failure in the remaining untested dwelling units in the group. The ECC-Rater shall transmit the re-sample test results to the ECC- Provider registry, whereupon the Provider shall make available to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry, a registered copy of the Certificate of Verification for the remaining dwelling units in the group including the dwelling unit in the re-sample.
p.314If field verification and diagnostic testing of the second sample results in a failure, the ECC-Rater shall report the second failure to the ECC-Provider, the builder, and the enforcement agency. All dwelling units in the group must thereafter be individually field verified and diagnostically tested
p.314Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Proceduresp.315
p.3152025 Residential Appendices to confirm compliance for the feature that failed to comply with re-sampling. In cases where corrective action would require destruction of building components, the builder may choose to reanalyze compliance and choose different measures that will achieve compliance. In this case a new Certificate of Compliance shall be completed and submitted to the ECC-Provider, the ECC- Rater, and the enforcement agency. Even with a new Certificate of Compliance, the dwelling unit must be individually field verified and diagnostically tested. Upon verification of compliance, the ECC-Rater shall enter the test results into the ECC-Provider data registry. Whereupon the Provider shall make available to the ECC-Rater, the builder, the enforcement agency, and other authorized users of the ECC-Provider data registry, a registered copy of the Certificate of Verification for each individual dwelling in the group.