p.303RA2.4 Summary of Responsibilities
p.303Section RA2.4 summarizes responsibilities set forth in Appendix RA2 and organizes them by the responsible party. This section is not, however, a complete accounting of the responsibilities of the respective parties.
p.303RA2.4.1 Builder
p.303The builder shall make arrangements for submittal of the Certificate of Compliance information and certification signatures to the ECC-Provider data registry for dwelling units with fe atures that require verification. The builder shall make arrangements for the services of a certified ECC-Rater prior to installation of the features, so that once the installation is complete the ECC-Rater has ample time to complete the field verification and diagnostic testing without delaying final approval of the building permit by the enforcement agency. The Builder shall make available to the ECC-Rater a copy of the Certificate of Compliance that was approved/signed by the building designer or owner and submitted to the enforcement agency.
p.303The builder or subcontractor responsible for the installation shall complete and sign all applicable Certificates of Installation to certify that the installation work meets the requirements for compliance credit shown on the Certificate of Compliance and that all applicable field verification and diagnostic test results reported on Certificates of Installation are accurate. The builder or subcontractor shall post a copy of all applicable Certificates of Installation at the construction site for review by the enforcement agency in conjunction with requests for final inspection for each dwelling unit. Alternatively, the enforcement agency may elect to view the certificates on an
p.303Appendix RA2– Residential Field Verification and Diagnostic Testing Documentation Proceduresp.304
p.3042025 Residential Appendices approved Data Registry. The builder or subcontractor shall also make available to the ECC-Rater copies of all applicable Certificates of Installation.
p.304If the builder utilizes group sampling for verification compliance, the builder, builder’s authorized representative, or the ECC-Rater shall identify the dwelling units to be included in the sample group for field verification and diagnostic testing. The ECC-Rater, with no direction from the installer or builder, shall randomly select one dwelling unit from a sample group for field verification and diagnostic testing upon receiving the builder’s or builder representative’s request for verification of that group.
p.304The builder shall arrange for copies of all applicable registered Certificates of Verification to be posted at the building site for review by the enforcement agency in conjunction with requests for final inspection for each dwelling unit. Alternatively, the enforcement agency may elect to view the certificates on an approved Data Registry.
p.304When re-sampling reveals a failure (see Section RA2.6.4), the builder is required to offer at no charge to all building owners for occupied dwelling units in the group to complete field verification, diagnostic testing, and corrective action if necessary. Building owners may decline to have field verification and diagnostic testing and corrective action completed for the dwelling unit. The builder shall report the identifying location of any dwelling unit in which the building owner declines field verification and diagnostic testing and corrective action to the ECC-Provider. The builder shall take corrective action as required in all unoccupied dwelling units in the group and in occupied dwelling units in the group where building owners have accepted field verification, diagnostic testing, and corrective action.
p.304The builder shall leave in the building, for the building owner at occupancy, copies of all compliance, operating, maintenance, and ventilation information specified in applicable sections of Title 24, Part 1, Section 10-103(b).