Appendix JA16 – Criteria for Pool and/or Spa Heating

Figure on PDF page 277
Text in this figure

Joint Appendix JA16

p.277 Needs alt text review

p.277Appendix JA16 – Criteria for Pool and/or Spa Heating

p.277JA16.1 Systems Purpose and Scope

p.277Joint Appendix JA16 provides the eligibility criteria for energy efficiency measures for solar pool heating systems, sizing for heat pump pool heaters (HPPH), and on-site renewable energy or recovery energy.

p.277JA16.2 Solar Pool Heating Systems

p.277Solar pool heating systems shall be certified and rated by the Solar Rating and Certification Corporation (ICC-SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director.

p.277Solar thermal collectors shall be listed and labeled in accordance with Table 110.4-A. The installed system shall meet the following eligibility criteria:

p.277(a) The system shall be installed according to manufacturer’s instructions.

p.277(b) The system shall be installed in the exact configuration for which it was rated. The

p.277system shall have the same collector(s), piping, pump, vacuum relief valve, controls, and other components used to establish the rated condition.

p.277JA16.3 Heat Pump Pool Heater Sizing

p.277A heat pump pool heater (HPPH) shall be sized using the HPPH manufacturer’s specifications. The following sizing provisions shall be applicable if the HPPH manufacturer’s specifications do not include information on HPPH sizing:

p.277(a) Determine desired pool temperature in °F.

p.277(b) Determine average temperature for the coldest month of pool use in °F.

p.277(c) Determine temperature rise in °F by subtracting the average temperature for the

p.277coldest month from the desired pool temperature.

p.277(d) Calculate the pool volume in gallons.

p.277(e) Calculate the time needed for the HPPH to achieve the 10 °F degree rise in hours.

p.277This shall not exceed 17.5 hours.

p.277(f) Use equation JA16-1 to determine the Btu/h output requirement of the HPPH.

p.277Appendix JA16 – Criteria for Pool and Spa Heating Systemsp.278

p.2782025 Joint Appendices

Equation on PDF page 278: Vp x 8.33 x ΔT Qout= t

Equation text: Vp x 8.33 x ΔT Qout= t

Needs visual review

p.278

p.278Where:

p.278Qout is the output heating capacity of the HPPH

p.278Vp is the pool volume in gallons

p.2788.33 is the weight of a gallon of water at 62°F in pounds per gallon

p.278ΔT is the pool temperature rise in °F, and shall not exceed 10°F

p.278t is the time needed for the HPPH to achieve the 10 °F degree rise in hours and shall not exceed 17.5 hours