p.496Field Verification and Diagnostic Testing of Multifamily Dwelling Unit Compartmentalization
p.496NA2.3.1 Purpose and Scope
p.496The purpose of this test procedure is to measure and determine compliance with multifamily dwelling unit compartmentalization requirements .
p.496The measurement procedure shall be based on the specifications of Residential Energy Services Network's (RESNET) Standard for Testing Airtightness of Building, Dwelling Unit, and Sleeping Unit Enclosures; Airtightness of Heating and Cooling Air Distribution Systems; and Airflow of Mechanical Ventilation Systems (ANSI/RESNET/ICC 380-2019) (RESNET 380) as further specified in Subsections NA2.3.2, NA2.3.3, NA2.3.4 below.
p.496This enclosure leakage procedure is applicable to Multifamily dwelling unit enclosures.
p.496NA2.3.2 Instrument Specifications
p.496The instrumentation for the enclosure leakage measurements shall conform to the specifications in RESNET 380 Section 4.1.
p.496NA2.3.3 Enclosure Leakage Measurement Procedures
p.496The enclosure leakage measurement procedure shall conform to the following specifications:
p.4961) The procedure for preparation of the building or dwelling unit for testing shall conform to the applicable requirements in RESNET 380 Section 4.2.
p.4962) The procedure for installation of the test apparatus, and preparations for measurement shall conform to the applicable requirements in RESNET 380 Section 4.3.
p.496Appendix NA2 – Nonresidential Field Verification and Diagnostic Test Proceduresp.497
p.4972025 Nonresidential Appendices If compliance requires the results of the test to be reported in cubic feet per minute per ft2 of dwelling unit enclosure surface area at 50 Pa (0.2 inch water) (CFM50/ft2 of enclosure), the dwelling unit enclosure interior surface area in ft2 (compartmentalization boundary area) shall be recorded.
p.4973) The procedure for the conduct of the enclosure leakage test shall conform to the One-Point Airtightness Test specified in RESNET 380 Section 4.4.1 or the multi- point airtightness test specified in RESNET 380 Section 4.4.2.