Joint Appendix JA15

p.275 Needs alt text review

p.275Appendix JA15 – Qualification Requirements for Central Heat Pump Water Heater Ready

p.275JA15.1 Purpose and Scope

p.275Joint Appendix JA15 provides sizing requirements, for electric ready infrastructure installed with gas or propane water heating systems to meet the requirement for electric readiness specified in Title 24, Part 6, Section 160.9(f).

p.275JA15.2 Electric Ready Requirements

p.275JA15.2.1 Heat Pump Space Requirements

p.275Space shall be reserved for future installation of central heat pump water heaters. The space reserved shall meet the following requirements:

p.275(a) If the gas water heating system has an input capacity less than 200,000 Btu per

p.275hour, the minimum space reserved for the heat pump shall be 2.0 square feet per 10,000 Btu per hour input of the gas or propane water heating system, and the minimum linear dimension of the space reserved shall be 48 linear inches.

p.275(b) If the gas water heating system has an input capacity greater than or equal to

p.275200,000 Btu per hour, the minimum space reserved for the heat pump shall be 3.6 square feet per 10,000 Btu per hour input of the gas or propane water heating system, and the minimum linear dimension of the space reserved shall be 84 linear inches.

p.275JA15.2.2 Storage Tank Space Requirements

p.275Space shall be reserved for future installation of hot water storage tanks. The space reserved shall meet the following requirements:

p.275(a) If the input capacity of the gas water heating system is less than 200,000 Btu

p.275per hour, the minimum space reserved for the storage and temperature maintenance tanks shall be 4.4 square feet per 10,000 Btu per hour input of the gas or propane water heating system.

p.275(b) If the input capacity of the gas water heating system is greater than or equal to

p.275200,000 Btu per hour, the minimum physical space reserved for the storage and temperature maintenance tanks shall be 3.1 square feet per 10,000 Btu per hour input of the gas or propane water heating system.