JA7.7.1.2 Digital Data Sources External to a Data Registry

p.220JA7.7.1.2 Digital Data Sources External to a Data Registry

p.220As an alternative to the data entry described in JA7.7.1.1, digital data sources external to a Data Registry may be used by an authorized user of a Data Registry for transmitting information to a Data Registry during document registration procedures. External Digital Data Sources (EDDS) shall be approved by the Energy Commission in accordance with the applicable requirements specified in Sections JA7.8.

p.220JA7.7.1.2.1 EDDS Data Exchange Requirements

p.220The data uploads to an EDDS, and the data exchange between a Data Registry and an EDDS, including data upload and data exchange that is facilitated by an API, shall conform to the following:

p.220(a) The data exchange from an EDDS to a Data Registry shall be initiated only by an

p.220authorized user of the Data Registry; only while the user is logged into his Title 24, Part 6 Data Registry user account; and only by use of a data exchange feature managed and made available to the user by the Data Registry user interface.

p.220(b) The data exchange from an EDDS to a Data Registry shall not be an unattended

p.220automatic electronic data exchange transaction.

p.220(c) The Registration Provider shall ensure the authorized user has the opportunity to

p.220review and revise the information transmitted to the data registry by use of an EDDS prior to making electronic signature controls available to the user.

p.220(d) The Registration Provider shall be responsible for managing the security and

p.220integrity of the data exchange with the EDDS.

p.220(e) The Registration Provider shall ensure that user data uploads to the EDDS, and

p.220subsequent storage and maintenance of compliance data in the EDDS are done using best practices for secure data exchange and secure data storage.

p.220(f) The Registration Provider shall ensure that the data exchange processes that

p.220import data into the Data Registry from the EDDS are performed using best practices for secure data exchange.

p.220(g) The user's compliance data may be uploaded automatically to an EDDS datastore,

p.220such as by network-connected diagnostic field verification instruments, or it may be keyed in by the user using an EDDS services software user interface.

p.220(h) The data transmitted from an EDDS to a Data Registry shall conform to the XML

p.220schema for each respective Title 24, Part 6 compliance document for which the data is to be used. All data provided to complete compliance documents shall be subjected to data validation by the Data Registry software after the data is transmitted to the Data Registry.

p.220(i) The current compliance document schemas approved by the Energy Commission

p.220shall be made available to the EDDS services providers as needed in order to clarify the Title 24 Part 6 compliance document data requirements.

p.220(j) Examples and additional guidance for how to comply with Joint Appendix JA7

p.220regarding interfacing with and managing EDDS technical features are included in the Data Registry Requirements Manual.

p.220Appendix JA7 – Data Registry Requirements