5. Floors shall meet the following requirements:

p.554TABLE 170.2-A ENVELOPE COMPONENT PACKAGE – Multifamily Standard Building Design (continued)

p.555TABLE 170.2-A ENVELOPE COMPONENT PACKAGE – Multifamily Standard Building Design (continued)

p.556If using F-factor to comply, use Reference Joint Appendices JA4, Table 4.4.7 to determine alternate depth and R-value to be less than or equal to the required maximum F- Option B meets §170.2(a)1Bii 10. Option C meets §170.2(a)1BIiii 11. Option D meets §170.2(a)1Biv

p.552a. the lower-rated labeled SHGC shall be used with automatic controls to modulate the

TABLE 170.2-A ENVELOPE COMPONENT PACKAGE – Multifamily Standard Building Design p.553 Download CSV
Building Component - Roofs and CeilingsCZ 1CZ 2CZ 3CZ 4CZ 5CZ 6CZ 7CZ 8CZ 9CZ 10CZ 11CZ 12CZ 13CZ 14CZ 15CZ 16
Option B9 Below Roof Deck Insulation 1,2 (with air space)NRNRNRR19NRNRNRR19R19R13R19R19R19R19R19R13
Option B9 Ceiling InsulationR 38R 38R 30R 38R 30R 30R 30R 38R 38R 38R 38R 38R 38R 38R 38R 38
Option B9 Radiant BarrierNRREQREQNRREQREQREQNRNRNRNRNRNRNRNRNR
Option B9 Low-Slope-Aged Solar ReflectanceNRNRNRNRNRNRNRNRNRNRNRNR0.63NR0.63NR
Option B9 Low-Sloped-Thermal EmittanceNRNRNRNRNRNRNRNRNRNRNRNR0.75NR0.75NR
Option B9 Low-Sloped-Solar Reflectance IndexNRNRNRNRNRNRNRNRNRNRNRNR75NR75NR
Option B9 Steep-Sloped-Aged Solar ReflectanceNRNRNRNRNRNRNRNRNR0.250.250.200.250.200.25NR
Option B9 Steep-Sloped-Thermal EmittanceNRNRNRNRNRNRNRNRNR0. 750.750.750.750.750.75NR
Option B9 Steep-Sloped-Solar Reflectance IndexNRNRNRNRNRNRNRNRNR232316231623NR
Option C10-Ceiling InsulationR 38R 30R 30R 30R 30R 30R 30R 30R 30R 30R 38R 38R 38R 38R 38R 38
Option C10-Radiant BarrierNRREQREQREQREQREQREQREQREQREQREQREQREQREQREQNR
Option C10 Low-Sloped-Aged Solar ReflectanceNRNRNRNRNRNRNRNRNRNRNRNR0.63NR0.63NR
Option C10 Low-Sloped-Thermal EmittanceNRNRNRNRNRNRNRNRNRNRNRNR0.75NR0.75NR
Option C10 Low-Sloped-Solar Reflectance IndexNRNRNRNRNRNRNRNRNRNRNRNR75NR75NR
Option C10 Steep-Sloped-Aged Solar ReflectanceNRNRNRNRNRNRNRNRNR0.200.200.200.200.200.20NR
Option C10 Steep-Sloped-Thermal EmittanceNRNRNRNRNRNRNRNRNR0. 750.750.750.750.750.75NR
Option C10 Steep-Sloped-Solar Reflectance IndexNRNRNRNRNRNRNRNRNR161616161616NR
Option D11-Metal Building U-factor0.0410.0410.0410.0410.0410.0410.0410.0410.0410.0410.0410.0410.0410.0410.0410.041
Option D11-Wood Framed and Other U-factor0.0280.0280.0340.0280.0340.0340.0390.0280.0280.0280.0280.0280.0280.0280.0280.028
Option D11 Low-Sloped-Aged Solar ReflectanceNR0.63NR0.63NR0.630.630.630.630.630.630.630.630.630.63NR
Option D11 Low-Sloped-Thermal EmittanceNR0.75NR0.75NR0.750.750.750.750.750.750.750.750.750.75NR
Option D11 Low-Sloped-Solar Reflectance IndexNR75NR75NR75757575757575757575NR
Option D11 Steep-Sloped-Aged Solar ReflectanceNR0.200.200.200.200.200.200.200.200.200.200.200.200.200.20NR
Option D11 Steep-Sloped-Thermal EmittanceNR0.750.750.750.750.750.750.750.750.750.750.750.750.750.75NR
Option D Steep-Sloped-Solar Reflectance IndexNR1616161616161616161616161616NR
ENVELOPE COMPONENT PACKAGE – Multifamily Standard Building DesignBuilding Component - Fenestrations p.555 Download CSV
Building Component - FenestrationCZ 1CZ 2CZ 3CZ 4CZ 5CZ 6CZ 7CZ 8CZ 9CZ 10CZ 11CZ 12CZ 13CZ 14CZ 15CZ 16
Curtain Wall/ Storefront7 - Maximum U-factor0.380.410.410.410.410.410.410.410.410.410.410.410.410.410.410.38
Curtain Wall/ Storefront7 - Maximum RSHGCNR0.26NR0.26NR0.260.260.260.260.260.260.260.260.250.26NR
Curtain Wall/ Storefront7 - Minimum VT, common use area0.460.460.460.460.460.460.460.460.460.460.460.460.460.460.460.46
NAFS 2017 Performance Class AW5 - Maximum U-factor0.380.400.400.400.400.400.400.400.400.400.400.400.400.400.400.38
NAFS 2017 Performance Class AW5 - Maximum RSHGCNR0.24NR0.24NR0.240.240.240.240.240.240.240.240.240.24NR
NAFS 2017 Performance Class AW5 - Minimum VT, common use areas0.370.370.370.370.370.370.370.370.370.370.370.370.370.370.370.37
All Other Fenestration - Maximum U- factor0.280.300.280.280.280.340.340.300.300.300.280.300.280.280.280.28
All Other Fenestration - Maximum RSHGCNR0.23NR0.23NR0.230.230.230.230.230.230.230.230.230.23NR
Maximum Window to Floor Ratio20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%
Maximum Window to Wall Ratio40%40%40%40%40%40%40%40%40%40%40%40%40%40%40%40%
Maximum Skylight Roof Ratio5%5%5%5%5%5%5%5%5%5%5%5%5%5%5%5%
ENVELOPE COMPONENT PACKAGE – Multifamily Standard Building DesignBuilding Component - Walls, Floors, Doors, and QII p.554 Download CSV
Building Component - Walls, Floors, Doors, and QIICZ 1CZ 2CZ 3CZ 4CZ 5CZ 6CZ 7CZ 8CZ 9CZ 10CZ 11CZ 12CZ 13CZ 14CZ 15CZ 16
Walls - Metal Building - Any Fire Rating0.0610.0610.0610.0610.0610.0610.0610.0610.0610.0610.0570.0570.0570.0570.0570.057
Walls - Framed (wood, metal) and other - >1hr fire rating0.0590.0590.0590.0590.0590.0650.0650.0590.0590.0590.0510.0590.0590.0510.0510.051
Walls - Framed (wood, metal) and other - ≤1hr fire rating30.0510.0510.0510.0510.0510.0650.0650.0510.0510.0510.0510.0510.0510.0510.0510.051
Walls - Mass Light4U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.077 R 13U 0.059 R 17
Walls - Mass Heavy0.2530.6500.6500.6500.6500.6900.6900.6900.6900.6500.1840.2530.2110.1840.1840.160
Floors/Soffits - Slab Perimeter8NRNRNRNRNRNRNRNRNRNRNRNRNRNRNRF 0.58 R 7.0
Floors/Soffits – Wood FramedU 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19U 0.037 R 19
Floors/Soffits - Raised MassU 0.092 R 8.0U 0.092 R 8.0U 0.269 R 0U 0.269 R 0U-0.269 R 0U 0.269 R 0U 0.269 R 0U 0.269 R 0U 0.269 R 0U 0.269 R 0U 0.092 R 8.0U 0.138 R 4.0U 0.092 R 8.0U 0.092 R 8.0U 0.138 R 4.0U 0.092 R 8.0
Floors/Soffits - Other0.0480.0390.0710.0710.0710.0710.0710.0710.0710.0710.0390.0710.0710.0390.0390.039
Exterior Doors6 - Max U- Factor Dwelling Unit Entry0.200.200.200.200.200.200.200.200.200.200.200.200.200.200.200.20
Exterior Doors6 - Max U-Factor Common Use Area Entry Non- Swinging0.501.451.451.451.451.451.451.451.451.451.451.451.451.451.450.50
Exterior Doors6 - Max U-Factor Common Use Area Entry Swinging0.700.700.700.700.700.700.700.700.700.700.700.700.700.700.700.70
Quality Insulation Installation up to 3 habitable storiesYesYesYesYesYesYesNRYesYesYesYesYesYesYesYesYes

p.552amount of heat flow into the space in multiple steps in response to daylight levels or solar intensity; and

p.552b. chromogenic glazing shall be considered separately from other glazing; and

p.552c. area-weighted averaging with other glazing that is not chromogenic shall not be

p.552permitted.

p.552iv. Haze value. Have a glazing material or diffuser that has a measured haze value greater

p.552than 90 percent, determined according to ASTM D1003 or other test method approved by the Energy Commission.

p.5524. All exterior doors, excluding glazed doors, that separate conditioned space from unconditioned space or from ambient air shall have a U-factor not greater than the applicable value in Table 170.2-A. Glazed doors must comply with the requirements of Section 170.2(a)3A.

p.554Common Use Area Entry Non-

p.5525. Floors shall meet the following requirements:

p.552A. Raised floors shall be insulated such that the floor assembly has an assembly U-factor equal

p.552to or less than shown in Table 170.2-A, or shall be insulated between wood framing with insulation having an R-value equal to or greater than shown in Table 170.2-A.

p.555Footnote requirements to TABLE 170.2-A:

p.552B. Slab floors shall have perimeter insulation installed with an F-factor equal to or less than or

p.555Install the specified R-value with an air space present between the roofing and the roof deck. Such as standard installation of concrete or clay tile. R-values shown for below roof deck insulation are for wood-frame construction with insulation installed between the framing members. Alternatives including insulation above rafters or above roof deck shall comply with the performance standards. Assembly U-factors for exterior framed walls can be met with cavity insulation alone or with continuous insulation alone, or with both cavity and continuous insulation that results in an assembly U-factor equal to or less than the U-factor shown. Use Reference Joint Appendices JA4 Table 4.3.1, 4.3.1(a), or Table 4.3.4 to determine alternative insulation products to be less than or equal to the required maximum U-factor. Mass wall has a heat capacity greater than or equal to 7.0 Btu/h-ft2. Product must be certified to meet the North American Fenestration Standard/Specification for an Architectural Window (AW). Glazed doors must meet the fenestration requirements. Requirements apply to doors included in the Curtainwall/Storefront construction assembly.p.556

p.552R-value equal to or greater than shown in Table 170.2-A. The minimum depth of concrete slab floor perimeter insulation shall be 16 inches or the depth of the footing of the building, whichever is less.

p.5526. All buildings up to three habitable stories shall comply with the quality insulation installation (QII) requirements shown in Table 170.2-A. When QII is required, insulation installation shall meet the criteria specified in Reference Appendix RA3.5.

p.553SECTION 170.2 – PRESCRIPTIVE APPROACH

p.554SECTION 170.2 – PRESCRIPTIVE APPROACH

p.555SECTION 170.2 – PRESCRIPTIVE APPROACH

p.556SECTION 170.2 – PRESCRIPTIVE APPROACH

p.552SECTION 170.2 – PRESCRIPTIVE APPROACH