Text in this table
(i) The performance approach requirements of Section 140.1; or (ii) The prescriptive approach requirements of Section 140.9. 3. New construction in existing buildings (additions, alterations and repairs). A. Nonresidential and hotel/motel buildings. Section 141.0 applies to new construction in existing nonresidential, high-rise residential, and hotel/motel buildings. New construction in existing buildings includes additions, alterations and repairs. Section 141.0 specifies requirements that uniquely apply to additions, alterations or repairs to existing buildings, and specify which requirements in other sections also apply. For alterations that change the occupancy classification of the building, the requirements specified in Section 141.0 apply to the occupancy after the alterations. B. Single-family buildings. Section 150.2 applies to new construction in existing single-family buildings. New construction in existing buildings includes additions, alterations and repairs. Section 150.2 specifies requirements that uniquely apply to additions, alterations or repairs to existing buildings, and specifies which requirements in other sections also apply. For alterations that change the occupancy classification of the building, the requirements specified in Section 150.2 apply to the occupancy after the alterations. C. Multifamily buildings. Section 180.0 applies to new construction in existing multifamily buildings. New construction in existing buildings includes additions, alterations and repairs. Section 180.0 specifies requirements that uniquely apply to additions, alterations or repairs to existing buildings, and specifies which requirements in other sections also apply. For alterations that change the occupancy classification of the building, the requirements specified in Section 180.0 apply to the occupancy after the alterations. 4. Installation of insulation in existing buildings. Section 110.8(d) applies to buildings in which insulation is being installed in existing attics, or on existing water heaters, or existing space conditioning ducts. 5. Outdoor lighting. Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 150.0 apply to newly constructed outdoor lighting systems, and Section 141.0 applies to outdoor lighting that is either added or altered. 6. Signs. Sections 130.0, 130.3 and 140.8 apply to newly constructed signs located either indoors or outdoors and Section 141.0 applies to sign alterations located either indoors or outdoors. (f) Mixed occupancy. When a building is designed and constructed for more than one type of occupancy (residential and nonresidential), the space for each occupancy shall meet the provisions of Part 6 applicable to that occupancy. Exception 1 to Section 100.0(f): If one occupancy constitutes at least 80 percent of the conditioned floor area of the building, the entire building envelope, HVAC, and water heating may be designed to comply with the provisions of Part 6 applicable to that occupancy, provided that the applicable lighting requirements in Sections 140.6 through 140.8, 150.0(k), or 160.5 and 170.2(e) are met for each occupancy and space, and mandatory measures in Sections 110.0 through 130.5, 150.0, and 160.0 through 160.9 are met for each occupancy and space. Exception 2 to Section 100.0(f): If one occupancy constitutes at least 90 percent of the combined conditioned plus unconditioned floor area of the building, the entire building indoor lighting may be designed to comply with only the lighting provisions of Part 6 applicable to that occupancy. (g) Administrative requirements. Administrative requirements relating to permit requirements, enforcement by the Commission, locally adopted energy standards, interpretations, claims of exemption, approved calculation methods, rights of appeal, and certification and labeling requirements of fenestration products and roofing products are specified in California Code of Regulations, Title 24, Part 1, Sections 10-101 to 10-114. (h) Certification Requirements for Manufactured Equipment, Products, and Devices. Part 6 limits the installation of manufactured equipment, products, and devices to those that have been certified as specified by sections 110.0 and 110.1. Requirements for manufactured equipment, products, and devices, when not specified in Title 24 Part 6, are specified in California Code of Regulations, Title 20, Sections 1601-1609.
| Occupancies | Application | Mandatory | Prescriptive | Performance | Additions Alterations |
|---|---|---|---|---|---|
| Demand Responsive (DR) Controls | DR Lighting Controls | 110.12 | 140.6(a)2K; 170.2(e)2Bxi | N.A. | Table 141.0-F; Table 180.2-E |
| Demand Responsive (DR) Controls | DR Electronic Message Center Control | 110.12, 130.3(a)3 | NA | NA | NA |
| Demand Responsive (DR) Controls | DR Controlled Receptacles | 110.12, 130.5(e), 160.6(e) | NA | NA | NA |
| Signs | Indoor and Outdoor | 110.9, 130.0, 130.3, 160.5(d) | 140.8, 170.2(e)7 | N.A. | 141.0, 141.0(b)2H, 180.2(b)4Bvi |
| Single-Family | General | 150.0 | 150.1(a, c) | 150.1(a), 150.1(b) | 150.2(a), 150.2(b) |
| Single-Family | Envelope (conditioned) | 110.6, 110.7, 110.8, 150(a), 150.0(b), 150.0(c), 150.0(d), 150.0(e), 150.0(g), 150.0(q) | 150.1(a, c) | 150.1(a), 150.1(b) | 150.2(a), 150.2(b) |
| Single-Family | HVAC (conditioned) | 110.2, 110.5, 150.0(h), 150.0(i), 150.0(j), 150.0(m), 150.0(o) | 150.1(a, c) | 150.1(a), 150.1(b) | 150.2(a), 150.2(b) |
| Single-Family | Water Heating | 110.3, 150.0(j, n) | 150.1(a, c) | 150.1(a), 150.1(b) | 150.2(a), 150.2(b) |
| Single-Family | Indoor Lighting (conditioned, unconditioned and parking garages) | 110.9, 130.0, 150.0(k) | 150.1(a, c) | 150.1(a), 150.1(b) | 150.2(a), 150.2(b) |
| Single-Family | Outdoor Lighting | 110.9, 130.0,150.0(k) | 150.1(a, c) | 150.1(a), 150.1(b) | 150.2(a), 150.2(b) |
| Single-Family | Pool and Spa Systems | 110.4, 150.0(p) | N. A. | N.A. | 150.2(a), 150.2(b) |
| Single-Family | Solar Ready Buildings | 110.10 | N. A. | N.A. | N.A. |
| Single-Family | Electric Ready | 150.0(s), 150.0(t), 150.0(u), 150.0(v) | N.A. | N.A. | N.A. |
| Single-Family | Solar PV Systems | N.A. | 150.1(c)14 | 150.1(a), 150.1(b) | N.A. |
| Occupancies | Application | Mandatory | Prescriptive | Performance | Additions Alterations |
|---|---|---|---|---|---|
| All Buildings | General | 100.0, 100.1, 100.2, 110.0 | 100.0, 100.1, 100.2, 110.0 | 100.0, 100.1, 100.2, 110.0 | 100.0, 100.1, 100.2, 110.0 |
| Nonresidential, And Hotels/Motels | General | 120.0 | 140.0, 140.2 | 140.0, 140.1 | 141.0 |
| Nonresidential, And Hotels/Motels | Envelope (conditioned) | 110.6, 110.7, 110.8,120.7 | 140.3 | 140.0, 140.1 | 141.0 |
| Nonresidential, And Hotels/Motels | Envelope (unconditioned process spaces) | N.A. | 140.3(c) | 140.0, 140.1 | 141.0 |
| Nonresidential, And Hotels/Motels | HVAC (conditioned) | 110.2, 110.5, 120.1, 120.2, 120.3, 120.4, 120.5, 120.8, 120.10 | 140.4 | 140.0, 140.1 | 141.0 |
| Nonresidential, And Hotels/Motels | Water Heating | 110.3, 120.3, 120.8, 120.9 | 140.5 | 140.0, 140.1 | 141.0 |
| Nonresidential, And Hotels/Motels | Indoor Lighting (conditioned, process spaces) | 110.9, 120.8, 130.0, 130.1, 130.4 | 140.3(c), 140.6 | 140.0, 140.1 | 141.0 |
| Nonresidential, And Hotels/Motels | Indoor Lighting (unconditioned and parking garages) | 110.9, 120.8, 130.0, 130.1, 130.4 | 140.3(c), 140.6 | N.A. | 141.0 |
| Nonresidential, And Hotels/Motels | Outdoor Lighting | 110.9, 130.0, 130.2, 130.4 | 140.7 | N.A. | 141.0 |
| Nonresidential, And Hotels/Motels | Electrical Power Distribution | 110.11, 130.5 | N.A. | N.A. | 141.0 |
| Nonresidential, And Hotels/Motels | Pool and Spa Systems | 110.4, 110.5, 150.0(p) | N. A. | N.A. | 141.0 |
| Nonresidential, And Hotels/Motels | Solar Ready Buildings | 110.10 | N.A. | N.A. | 141.0(a) |
| Nonresidential, And Hotels/Motels | Solar PV and Battery Energy Storage Systems | N.A. | 140.10 | 140.0, 140.1 | N.A. |
| Covered Processes1 | Envelope, Ventilation, Process Loads | 110.2, 120.3, 120.6 | 140.9 | 140.1 | 110.2, 120.3, 120.6, 140.9, 141.1 |
| Demand Responsive (DR) Controls | DR Control Thermostats | JA5; Exception 5 to Section 110.10(b)1A; Exception 4 to Section 110.10(b)1B. | NA | NA | NA |
| Demand Responsive (DR) Controls | DR Zonal HVAC Controls | 110.12 | NA | NA | NA |
| Occupancies | Application | Mandatory | Prescriptive | Performance | Additions Alterations |
|---|---|---|---|---|---|
| Multifamily | General | 160.0 | 170.2 | 170.1 | 180.0 |
| Multifamily | Envelope (conditioned) | 110.6, 110.7, 110.8, 160.1 | 170.1(a) | 170.1 | 180.0 |
| Multifamily | Ventilation and Indoor Air Quality | 160.2 | N.A. | 170.1 | 180.0 |
| Multifamily | HVAC (conditioned) | 110.2, 110.5, 160.3 | 170.2(c) | 170.1 | 180.0 |
| Multifamily | Water Heating | 110.3, 160.4 | 170.2(d) | 170.1 | 180.0 |
| Multifamily | Indoor Lighting | 110.9, 160.5 | 170.2(e) | 170.1 | 180.0 |
| Multifamily | Outdoor Lighting | 110.9, 160.5 | 170.2(e) | 170.1 | 180.0 |
| Multifamily | Electrical Power Distribution | 110.11, 160.6 | N.A. | N.A. | 180.0 |
| Multifamily | Pool and Spa Systems | 110.4, 110.5, 160.7 | N.A. | N.A. | 180.0 |
| Multifamily | Solar Ready Buildings | 110.10, 160.8 | N.A. | N.A. | 180.0 |
| Multifamily | Electric Ready | 160.9 | N.A. | N.A. | N.A. |
| Multifamily | Solar PV and Battery Energy Storage Systems | N.A. | 170.2(f), (g), (h) | 170.1 | N.A. |
p.113SECTION 100.0 - SCOPE
p.114SECTION 100.0 - SCOPE
p.115SECTION 100.0 - SCOPE
p.116SECTION 100.0 - SCOPE
p.117SECTION 100.0 - SCOPE
p.118SECTION 100.0 - SCOPE