SECTION 140.1 – PERFORMANCE APPROACH: ENERGY BUDGETS

p.293SECTION 140.1 – PERFORMANCE APPROACH: ENERGY BUDGETS

p.293A building complies with the performance standards if the energy consumption calculated for the proposed design building is no greater than the energy budget calculated for the standard design building using Commission-certified compliance software as specified by Sections 10- 109(c) and 10-116.

p.293(a) Energy Budget. The energy budget is expressed in terms of long-term system cost (LSC) and

p.293source energy.

p.2931. Long-term system cost (LSC). The LSC energy budget is determined by applying the mandatory and prescriptive requirements of the standard design to the proposed design building and has two components, the Efficiency LSC and the Total LSC.

p.293A. The Efficiency LSC energy is the sum of the LSC energy for space-conditioning, water

p.293heating, mechanical ventilation, and lighting.

p.293B. The Total LSC energy is the sum of the Efficiency LSC energy and LSC energy from

p.293the photovoltaic system, battery energy storage systems (BESS) and demand flexibility.

p.2932. Source energy. The source energy budget is determined by applying the mandatory and prescriptive requirements of the standard design to the proposed design building.

p.293SECTION 140.1 – PERFORMANCE APPROACH: ENERGY BUDGETS