p.2012. A heat pump pool heater as the primary heating system that meets the sizing requirements of Reference Joint Appendix JA16.3. The supplementary heater can be of any energy source; or
p.200SECTION 110.4 – MANDATORY REQUIREMENTS FOR POOL AND SPA SYSTEMS AND EQUIPMENT
p.2013. A heating system that derives at least 60 percent of the annual heating energy from on-site renewable energy or on-site recovered energy.
p.2014. A combination of a solar pool heating system and heat pump pool heater without any additional supplementary heater; or
p.200(a) Certification by manufacturers. Any pool heater for a pool, spa, or a pool and spa combination shall be installed
p.200only if the manufacturer has certified that the system or equipment has all of the following:
p.2015. A pool heating system determined by the Executive Director to use no more energy than the systems specified in Items 1, 2, 3, or 4 above.
p.2001. Efficiency. Equipment subject to State or federal appliance efficiency standards shall comply with the applicable provisions of Section 110.1; and
p.2002. On-off switch. A readily accessible on-off switch, mounted on the outside of the heater that allows shutting off the heater without adjusting the thermostat setting; and
p.2003. Instructions. A permanent, easily readable and weatherproof plate or card that provides the energy efficiency rating and instruction for the energy efficient operation of the pool and/or spa heater; and
p.200(b) Installation. Any pool and/or spa system or equipment shall meet the following requirements:
p.2001. Heating Equipment. Equipment installed to heat water for pools and/or spas shall be selected from equipment meeting the standards shown in Table 110.4-A.
| Heating Energy Source | Standard |
|---|---|
| Electric Resistance | UL 1261 |
| Gas-fired | ANSI Z21.56/CSA 4.7a |
| Heat Pump | AHRI 1160 and one of the following: CSA C22.2 No. 236, UL 1995, or UL/CSA 60335-2-40 |
| Solar | ICC/APSP 902/SRCC 400 for solar pool heaters, ICC 901/SRCC 100 for solar collectors |
p.201(d) Controls for Heat Pump Pool Heaters with Supplementary Heating. Heat pump pool heaters with
p.201supplementary heaters shall have controls that meet the following:
p.2011. A Supplementary heater shall not operate when the heating load can be met by the heat pump pool heater alone; and
p.2012. The cut-on temperature for heat pump heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for heat pump heating is higher than the cut-off temperature for supplementary heating.SECTION 110.5 – NATURAL GAS CENTRAL FURNACES, COOKING EQUIPMENT, POOL AND SPA HEATERS, AND FIREPLACES: PILOT LIGHTS PROHIBITED
p.2002. Piping. At least 18 inches of horizontal or vertical pipe shall be installed between the filter and the heater or dedicated suction and return lines, or built-in or built-up connections shall be installed to allow for the future addition of solar heating equipment;
p.201Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light:
p.201(a) Fan-type central furnaces.
p.2003. Covers. Outdoor pools and/or spa with electric or gas heating equipment shall be installed with a pool cover.
p.201(b) Household cooking appliances.
p.2004. Directional inlets and time switches for pools. If the system or equipment is for a pool:
p.200i. The pool shall have directional inlets that adequately mix the pool water; and
p.201(c) Pool heaters.
p.200ii. A time switch or similar control mechanism shall be permanently installed as part of a pool water
p.200circulation control system that will allow all pumps to be set or programmed to run only during off-peak electric demand period, and for the minimum time necessary to maintain the water in the condition required by applicable public health standards.
p.201(d) Spa heaters.
p.201(e) Indoor and outdoor fireplaces.
p.200(c) Heating Source Sizing. Heating systems or equipment for pool and/or spas shall meet one of the sizing
p.200requirements 1 through 5 below:
p.2001. A solar pool heating system with a solar collector surface area that is equivalent to the following:
p.200A. For nonresidential and multifamily buildings, 65 percent or greater of the pool and/or spa surface area.
p.200B. For single family buildings, 60 percent or greater of the pool and/or spa surface area.p.201
p.200SECTION 110.4 – MANDATORY REQUIREMENTS FOR POOL AND SPA SYSTEMS AND EQUIPMENT