p.599vi. Lighting of public monuments.
p.600a. The general hardscape area of a site shall include parking lot(s), roadway(s),
p.601astronomy or nocturnal habitat of specific local fauna – shall be allowed a 2.0 lighting power allowance multiplier.
p.602TABLE 170.2-S ADDITIONAL MULTIFAMILY LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS (continued)
p.603TABLE 170.2-S ADDITIONAL MULTIFAMILY LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS (continued)
p.604v. Light emitting diodes (LEDs) with a power supply having an efficiency of 80 percent
p.605b. Local building code requirements if local building code requirements are
p.607rated PV system capacity for the building shall be determined by applying Equation 170.2-D to the conditioned floor area of each of the listed building types and summing the capacities determined for each.
| Primary Function Area | Allowed Lighting Power Density for General Lighting (W/ft2) | Additional Lighting Power Qualified Lighting Systems | Additional Lighting Power Additional Allowance (W/ft², unless noted otherwise) |
|---|---|---|---|
| Aging Eye/Low-vision6 Dining | 0.80 | Display/Decorative | 0.30 |
| Aging Eye/Low-vision6 Restroom | 1.00 | Display/Decorative | 0.20 |
p.602All area and distance measurements in plan view unless otherwise noted. PER APPLICATION: WATTAGE ALLOWANCE PER SPECIFIC AREA (W/ft2). Use as appropriate provided that none of the following specific applications shall be used for the same area.
p.603All area and distance measurements in plan view unless otherwise noted. PER SITE: WATTAGE ALLOWANCE PER HARDSCAPE AREA (W/ft2). May be used as additional allowance for applicable illuminated hardscape area on the site.
p.600driveway(s), sidewalk(s), walkway(s), bikeway(s), plaza(s), bridge(s), tunnel(s) and other improved area(s) that are illuminated. Public roadway(s) that are illuminated by a lighting system owned or maintained by the local municipality or utility shall not be included in the area calculations. In plan view of the site, determine the illuminated hardscape area, which is defined as any hardscape area that is within a square pattern around each luminaire or pole that is ten times the luminaire mounting height with the luminaire in the middle of the pattern, less any areas that are within a building, beyond the hardscape area, beyond property lines or obstructed by a structure. The illuminated hardscape area shall include portions of planters and landscaped areas that are within the lighting application and are less than or equal to 10 feet wide in the short dimensions and are enclosed by hardscape or other improvement on at least three sides. Multiply the illuminated hardscape area by the Area Wattage Allowance (AWA) from Table 170.2-R for the appropriate lighting zone.
p.604or greater; or
p.605confirmed by the Executive Director.
p.599vii. Lighting of signs complying with the requirements of Sections 160.5(d) and
p.599170.2(e)7.
| CLIMATE ZONE | A—CFA | B— DWELLING UNITS |
|---|---|---|
| 1 | 0.793 | 1.27 |
| 2 | 0.621 | 1.22 |
| 3 | 0.628 | 1.12 |
| 4 | 0.586 | 1.21 |
| 5 | 0.585 | 1.06 |
| 6 | 0.594 | 1.23 |
| 7 | 0.572 | 1.15 |
| 8 | 0.586 | 1.37 |
| 9 | 0.613 | 1.36 |
| 10 | 0.627 | 1.41 |
| 11 | 0.836 | 1.44 |
| 12 | 0.613 | 1.40 |
| 13 | 0.894 | 1.51 |
| 14 | 0.741 | 1.26 |
| 15 | 1.56 | 1.47 |
| 16 | 0.59 | 1.22 |
p.605EQUATION 170.2-C ANNUAL PHOTOVOLTAIC ELECTRICAL OUTPUT
p.6071. SARA includes the area of the building’s roof space capable of structurally supporting a PV system, and the area of all roof space on covered parking areas, carports and all other newly constructed structures on the site that are compatible with supporting a PV system per Title 24, Part 2, Section 1511.10.
p.599viii. Lighting of stairs, wheelchair elevator lifts for American with Disabilities Act
p.608including panels, modules, components, supports and attachments to the roof structure, to meet ASCE 7-16, Chapter 7, Snow Loads.
p.601All area and distance measurements in plan view unless otherwise noted. PER APPLICATION: WATTAGE ALLOWANCE PER APPLICATION. Use all that apply as appropriate.
p.602Lighting Application
p.602Zone 2
p.602Zone 3
p.603Lighting Application
p.603Zone 2
p.603Zone 3
Equation text: kWPV = (CFA × A)/1000 + (NDU × B)
Needs visual review
p.599(ADA) compliance, and ramps that are other than parking garage ramps.
| Lighting Application | Lighting Zone 0 | Lighting Zone 1 | Lighting Zone 2 | Lighting Zone 3 | Lighting Zone 4 |
|---|---|---|---|---|---|
| Building Entrances or Exits. Allowance per door. Luminaires qualifying for this allowance shall be within 20 feet of the door. | Not applicable | 9 watts | 15 watts | 19 watts | 21 watts |
| Primary Entrances to Senior Care Facilities Allowance per primary entrance(s) only. Primary entrances shall provide access for the general public and shall not be used exclusively for staff or service personnel. This allowance shall be in addition to the building entrance or exit allowance above. Luminaires qualifying for this allowance shall be within 100 feet of the primary entrance. | Not applicable | 20 watts | 40 watts | 57 watts | 60 watts |
| ATM Lighting. Allowance per ATM. Luminaires qualifying for this allowance shall be within 50 feet of the dispenser. | Not applicable | 100 watts for first ATM, 35 watts for each additional ATM. | 100 watts for first ATM, 35 watts for each additional ATM | 100 watts for first ATM, 35 watts for each additional ATM | 100 watts for first ATM, 35 watts for each additional ATM |
| Lighting Application | Lighting Zone 0 | Lighting Zone 1 | Lighting Zone 2 | Lighting Zone 3 | Lighting Zone 4 |
| Building Facades. Only areas of building façade that are illuminated shall qualify for this allowance. Luminaires qualifying for this allowance shall be aimed at the façade and shall be capable of illuminating it without obstruction or interference by permanent building features or other objects. This allowance calculation shall not include portions of the building facades within 20 feet of residence bedroom windows. | Not applicable | No Allowance | 0.100 W/ft² | 0.170 W/ft² | 0.225 W/ft² |
| Canopies and Tunnels. Allowance for the total area within the drip line of the canopy or inside the tunnel. Luminaires qualifying for this allowance shall be located under the canopy or tunnel. | Not applicable | 0.057 W/ft² | 0.137 W/ft² | 0.270 W/ft² | 0.370 W/ft² |
| Student Pick-up/Drop-off zone. Allowance for the area of the student pick-up/drop-off zone, with or without canopy, for preschool through 12th grade school campuses. A student pick-up/drop off zone is a curbside, controlled traffic area on a school campus where students are picked-up and dropped off from vehicles. The allowed area shall be the smaller of the actual width or 25 feet, times the smaller of the actual length or 250 feet. Qualifying luminaires shall be within 2 mounting heights of the student pick- up/drop-off zone. | Not applicable | No Allowance | 0.056 W/ft² | 0.200 W/ft² | No Allowance |
| Outdoor Dining. Allowance for the total illuminated hardscape of outdoor dining. Outdoor dining areas are hardscape areas used to serve and consume food and beverages. Qualifying luminaires shall be within 2 mounting heights of the hardscape area of outdoor dining. | Not applicable | 0.004 W/ft² | 0.030 W/ft² | 0.050 W/ft² | 0.075 W/ft² |
| Lighting Application | Lighting Zone 0 | Lighting Zone 1 | Lighting Zone 2 | Lighting Zone 3 | Lighting Zone 4 |
| Security Camera. This additional allowance is for the illuminated general hardscape area. This allowance shall apply when a security camera is installed within 2 mounting heights of the general hardscape area and mounted more than 10 feet away from a building. | Not applicable | No Allowance | 0.018 W/ft² | 0.018 W/ft² | 0.018 W/ft² |
p.598Footnotes for this table are listed below.
p.6072. SARA does not include:
p.605kWPV = kWdc size of the PV system.
p.599xi. Lighting for outdoor theatrical and other outdoor live performances, provided
p.5981. Detailed task work – Lighting provides high level of visual acuity required for activities with close attention to small elements and/or extreme close up work. 2. MH denotes the luminaire mounting height of the qualified lighting systems. 3. Daylight Adaptation Zones shall be no longer than 66 feet from the entrance to the parking garage. 4. RESERVED 5. Portable lighting in office areas includes under shelf or furniture-mounted supplemental task lighting qualifies when controlled by a time clock or an occupancy sensor. 6. Aging Eye/Low-vision areas can be documented as being designed to comply with the light levels in ANSI/IES RP-28 and are or will be licensed by local or state authorities for either senior long-term care, adult day care, senior support, and/or people with special visual needs. 7. Transition lighting OFF at night. Lighting power controlled by astronomical time clock or other control to shut off lighting at night. Additional LPD only applies to area within 30 feet of an exit. Not applicable to lighting in daylit zones. 8. Tunable white luminaires capable of color change greater than or equal to 2000K CCT, or dim-to-warm luminaires capable of color change greater than or equal to 500K CCT, connected to controls that allows color changing of the luminaires.
Equation text: CFA = Conditioned floor area.
Needs visual review
p.607A. Any area that has less than 70 percent annual solar access. Annual solar access is
p.599that these lighting systems are additions to area lighting systems and are controlled by a multi-scene or theatrical cross-fade control station accessible only to authorized operators.
p.607determined by dividing the total annual solar insolation (accounting for shading obstructions) by the total annual solar insolation if the same areas were unshaded by those obstructions. For all roofs, all obstructions including those that are external to the building, and obstructions that are part of the building design and elevation features, may be considered for the annual solar access calculations.
Equation text: NDU = Number of dwelling units.
Needs visual review
p.6037. Requirements for signs. Section 170.2(e)7 applies to all internally illuminated and externally illuminated signs, unfiltered light emitting diodes (LEDs), and unfiltered neon, both indoor and outdoor. Each sign shall comply with either Subsection A or B, as
Equation text: A = CFA adjustment factor from Table 170.2-T.
Needs visual review
p.599xii. Outdoor lighting systems for qualified historic buildings, as defined in the
Equation text: B = Dwelling unit adjustment factor from Table 170.2-T
Needs visual review
p.599California Historic Building Code (Title 24, Part 8), if they consist solely of historic lighting components or replicas of historic lighting components. If lighting systems for qualified historic buildings contain some historic lighting components or replicas of historic components, combined with other lighting components, only those historic or historic replica components are exempt. All other outdoor lighting systems for qualified historic buildings shall comply with Section 170.2(e)6.
p.603A. Maximum allowed lighting power.
p.600b. Determine the Initial Wattage Allowance (IWA) for general hardscape lighting
p.607B. Occupied roofs as specified by CBC Section 503.1.4.
p.604(f) Photovoltaic requirements—three habitable stories or fewer. All multifamily buildings up
p.600from Table 170.2-R for the appropriate lighting zone. The hardscape area shall be permitted one IWA per site.
p.603i. For internally illuminated signs, the maximum allowed lighting power shall not
p.604to three habitable stories shall have a newly installed photovoltaic (PV) system or newly installed PV modules meeting the minimum qualification requirements specified in Joint Appendix JA11. The annual electrical output of the PV system shall be no less than the smaller of a PV system size determined using Equation 170.2-C, or the total Solar Access Roof Area (SARA) multiplied by 18 for steep-sloped roofs or SARA multiplied by 14 for low- sloped roofs. A. SARA includes the area of the building’s roof space capable of structurally supporting a
p.603exceed the product of the illuminated sign area and 12 watts per square foot. For double-faced signs, only the area of a single face shall be used to determine the allowed lighting power.
p.607C. Roof area that is otherwise not available due to compliance with:
p.600c. The general hardscape lighting allowance shall be the sum of the allowed
p.607i. Other state building code requirements, or
p.600watts determined from a and b above.
p.599B. Outdoor lighting power trade-offs. Outdoor lighting power trade-offs shall be
p.607ii. Local building code requirements if the local building code requirements are confirmed by the Executive Director.
p.603ii. For externally illuminated signs, the maximum allowed lighting power shall not
p.600ii. Additional lighting power allowance for specific applications. Additional lighting
p.599determined as follows:
p.603exceed the product of the illuminated sign area and 2.3 watts per square foot. Only areas of an externally lighted sign that are illuminated without obstruction or interference, by one or more luminaires, shall be used.
p.600power for specific applications shall be the smaller of the additional lighting allowances for specific applications determined in accordance with Table 170.2-S for the appropriate lighting zone, or the actual installed lighting power meeting the requirements for the allowance.
p.601All area and distance measurements in plan view unless otherwise noted. PER APPLICATION: WATTAGE ALLOWANCE PER HARDSCAPE AREA (W/ft2). May be used for any illuminated hardscape area on the site.
p.599i. Allowed lighting power determined according to Section 170.2(e)6Di for general
p.607EQUATION 170.2-D PHOTOVOLTAIC DIRECT CURRENT CAPACITY
p.604PV system, and the area of all roof space on covered parking areas, carports, and all other newly constructed structures on the site that are compatible with supporting a PV system per Title 24, Part 2, Section 1511.10.
p.602Outdoor Dining. Allowance for the total illuminated hardscape of outdoor dining. Outdoor dining areas are hardscape areas used to serve and consume food and beverages. Qualifying luminaires shall be within 2 mounting heights of the hardscape area of outdoor dining.
p.599hardscape lighting allowance may be traded to specific applications in Section 170.2(e)6Dii, provided the hardscape area from which the lighting power is traded continues to be illuminated in accordance with Section 170.2(e)6Dia.
p.598A. A multifamily or mixed occupancy outdoor lighting installation complies with this
Equation text: kWPVdc = (CFA × A)/1000
Needs visual review
p.603iii. Lighting for unfiltered light emitting diodes (LEDs) and unfiltered neon shall
| Lighting Application | Lighting Zone 0 | Lighting Zone 1 | Lighting Zone 2 | Lighting Zone 3 | Lighting Zone 4 |
|---|---|---|---|---|---|
| Hardscape Ornamental Lighting. Allowance for the total site illuminated hardscape area. Luminaires qualifying for this allowance shall be rated for 50 watts or less as determined in accordance with Section 160.5(b)1 and shall be post-top luminaires, lanterns, pendant luminaires, or chandeliers. | Not applicable | No Allowance | 0.007 W/ft² | 0.013 W/ft² | 0.019 W/ft² |
| Lighting Application | Lighting Zone 0 | Lighting Zone 1 | Lighting Zone 2 | Lighting Zone 3 | Lighting Zone 4 |
| Special Security Lighting for Retail Parking and Pedestrian Hardscape. This additional allowance is for illuminated retail parking and pedestrian hardscape identified as having special security needs. This allowance shall be in addition to the building entrance or exit allowance. | Not applicable | 0.004 W/ft² | 0.005 W/ft² | 0.010 W/ft² | No Allowance |
p.598section if it meets the requirements in Subsections 170.2(e)6B and C, and the actual outdoor lighting power installed is no greater than the allowed outdoor lighting power calculated under Subsection 170.2(e)6D. The allowed outdoor lighting shall be calculated according to outdoor lighting zone in Title 24, Part 1, Section 10-114.
p.6020.030
p.6020.050 0.075 W/ft2
p.603comply with Section 170.2(e)7B.
p.600TABLE 170.2-R GENERAL HARDSCAPE MULTIFAMILY LIGHTING POWER ALLOWANCE
p.599ii. Allowed lighting power determined according to Section 170.2(e)2Dii for additional
p.603B. Alternate lighting sources. The sign shall be equipped with one or more of the
Equation text: kWPVdc = Minimum rated PV system capacity in kW.
Needs visual review
p.604B. SARA does NOT include:
p.605a. Shading from roof designs and configurations for steep slope roofs shall be considered
| Type of Power Allowance | Lighting Zone 02 | Lighting Zone 12 | Lighting Zone 22 | Lighting Zone 32 | Lighting Zone 42 |
|---|---|---|---|---|---|
| Area Wattage Allowance (AWA) | No allowance1 | 0.026 W/ft² | 0.030 W/ft² | 0.038 W/ft² | 0.055 W/ft² |
| Initial Wattage Allowance (IWA) | No allowance1 | 300 W | 350 W | 400 W | 450 W |
p.599lighting power allowances for specific applications shall not be traded between specific applications, or to hardscape lighting in Section 170.2(e)6Di.
p.603following light sources:
p.605for the annual solar access calculations; and
p.607= Conditioned floor area in square feet.
p.604i. Any roof area that has less than 70 percent annual solar access. Annual solar access
p.598Exceptions to Section 170.2(e)6A: When more than 50 percent of the light from a luminaire falls within one or more of the following applications, the lighting power for that luminaire shall not be required to comply with Section 170.2(e)6:
p.602TABLE 170.2-S ADDITIONAL MULTIFAMILY LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS (continued)
p.604is determined by dividing the total annual solar insolation, accounting for shading obstructions, by the total annual solar insolation if the same areas were unshaded by obstructions. For steep-sloped roofs, only shading from existing permanent natural or manmade obstructions that are external to the dwelling, including but not limited to trees, hills and adjacent structures, shall be considered for annual solar access calculations. For low slope roofs, all obstructions including those that are external to the dwelling unit, and obstructions that are part of the building design and elevation features, shall be considered for the annual solar access calculations.
p.607= PV capacity factor in W/square foot as specified in Table 170.2-U for the building type.
p.605b. Roof areas that are not allowed to have PVs by the mandatory conditions of approval
p.599iii. Trading off lighting power allowances between outdoor and indoor areas shall not be
p.602All area and distance measurements in plan view unless otherwise noted. PER SITE: WATTAGE ALLOWANCE PER HARDSCAPE AREA (W/ft2). May be used as additional allowance for applicable illuminated hardscape area on the site.
p.605shall not be considered in determining the SARA.
p.599permitted.
p.603iii. Neon or cold cathode lamps with transformer or power supply efficiency greater
p.598i. Temporary outdoor lighting.
p.599C. Calculation of actual lighting power. The wattage of outdoor luminaires shall be
p.603than or equal to the following:
p.599determined in accordance with Section 160.5(b)1.
p.602Lighting Application
p.602Zone 1
p.602Zone 2
p.602Zone 3
p.602Zone 4 Special Security Lighting for Retail Parking and Pedestrian Hardscape. This additional allowance is for illuminated retail parking and pedestrian hardscape identified as having special security needs. This allowance shall be in addition to the building entrance or exit allowance.
p.606(g) Photovoltaic requirements—more than three habitable stories. All newly constructed
p.598ii. Lighting required and regulated by the Federal Aviation Administration and the
p.603a. A minimum efficiency of 75 percent when the transformer or power supply
p.598Coast Guard.
p.599D. Calculation of allowed lighting power. The allowed lighting power shall be the
p.603rated output current is less than 50 mA; or
p.606building types specified in Table 170.2-U, or mixed occupancy buildings where at least 80 percent of the floor area of the building serves one or more of these building types shall have a newly installed photovoltaic (PV) system meeting the minimum qualification requirements of Reference Joint Appendix JA11. The PV capacity in kWdc shall not be less than the smaller of the minimum rated PV system capacity determined by Equation 170.2-D, or the total of all available Solar Access Roof Areas (SARA) multiplied by 18 for steep-sloped roofs or multiplied by 14 for low-sloped roofs. In mixed occupancy buildings, the minimump.607
p.599combined total of the sum of the general hardscape lighting allowance determined in accordance with Section 170.2(e)2Di, and the sum of the additional lighting power allowance for specific applications determined in accordance with Section 170.2(e)6Dii.
p.600Footnotes to TABLE 170.2-R:
p.602Not applicable 0.004 W/ft2 0.005 W/ft2 0.010 W/ft2 No Allowancep.603
p.598iii. Lighting for public streets, roadways, highways and traffic signage lighting,
p.603b. A minimum efficiency of 68 percent when the transformer or power supply
p.6001. Continuous lighting is explicitly prohibited in Lighting Zone 0. A single luminaire of 15 Watts or less may be installed at an entrance to a parking area, trail head, fee payment kiosk, outhouse, or toilet facility, as required to provide safe navigation of the site infrastructure. Luminaires installed shall meet the maximum zonal lumen limits as specified in Section 160.5(c)1. 2. Narrow band spectrum light sources with a dominant peak wavelength greater than 580 nm – as mandated by local, state, or federal agencies to minimize the impact on local, active professionalp.601
p.598including lighting for driveway entrances occurring in the public right-of-way owned or maintained by a local municipality or utility.
p.603rated output current is 50 mA or greater.
p.604ii. Occupied roof areas as specified by CBC Section 503.1.4.
p.603The ratio of the output wattage to the input wattage is at 100 percent tubing load.
p.599i. General hardscape lighting allowance. Determine the general hardscape lighting
p.598iv. Lighting for sports and athletic fields, and children’s playgrounds.
p.599power allowances as follows:p.600
p.604iii. Roof area that is otherwise not available due to compliance with:
p.603iv. Reservedp.604
p.598v. Reserved.p.599
p.604a. Other state building code requirements, orp.605
p.598SECTION 170.2 – PRESCRIPTIVE APPROACH
p.599SECTION 170.2 – PRESCRIPTIVE APPROACH
p.600SECTION 170.2 – PRESCRIPTIVE APPROACH
p.601SECTION 170.2 – PRESCRIPTIVE APPROACH
p.602SECTION 170.2 – PRESCRIPTIVE APPROACH
p.603SECTION 170.2 – PRESCRIPTIVE APPROACH
p.604SECTION 170.2 – PRESCRIPTIVE APPROACH
p.605SECTION 170.2 – PRESCRIPTIVE APPROACH
p.606SECTION 170.2 – PRESCRIPTIVE APPROACH