1. Envelope.

p.6202025 Building Energy Efficiency Standards

p.6222025 Building Energy Efficiency Standards

p.6242025 Building Energy Efficiency Standards

p.6192025 Building Energy Efficiency Standards

p.6212025 Building Energy Efficiency Standards

p.6232025 Building Energy Efficiency Standards

p.6193. Floor insulation. For the altered portion of raised floors that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable requirements of Items A through B below:

p.620b. Buildings with a radiant barrier in the attic, where the radiant barrier is not

p.621b. In Climate Zones 2 and 11 through 16, air seal all accessible areas of the

p.622b. The area-weighted U-factor and RSHGC of Table 170.2-A.

p.620installed directly above spaced sheathing, meeting the requirements of Section 170.2(a)1C; or

p.621ceiling plane between the attic and the conditioned space in accordance with Section 110.7; and

p.624Table 180.2-B Altered Fenestration Maximum U-Factor and Maximum SHGC and RSHGC, Minimum VT (Continued)

p.623Table 180.2-B Altered Fenestration Maximum U-Factor and Maximum SHGC and RSHGC, Minimum VT

p.619A. Raised framed floors. A minimum of R-11 insulation between framing members, or

p.620c. Buildings that have no ducts in the attic in Climate Zones 2, 4, 9, 10, 12 and

Altered Fenestration Maximum U-Factor and Maximum RSHGCI p.623 Download CSV
Building TypeFeatureCZ 1CZ 2CZ 3CZ 4CZ 5CZ 6CZ 7CZ 8CZ 9CZ 10CZ 11CZ 12CZ 13CZ 14CZ 15CZ 16
Curtainwall / Storefront / Window Wall1U-factor0.380.410.410.410.410.410.410.410.410.410.410.410.410.410.410.38
Curtainwall / Storefront / Window Wall1RSHGCNR0.26NR0.26NR0.260.260.260.260.260.260.260.260.260.26NR
Curtainwall / Storefront / Window Wall1VT20.460.460.460.460.460.460.460.460.460.460.460.460.460.460.460.46
NAFS 2017 Performance Class AW Window – FixedU-factor0.380.380.380.380.380.470.470.410.410.380.380.380.380.380.380.38
NAFS 2017 Performance Class AW Window – FixedRSHGCNR0.25NR0.25NR0.310.310.260.260.250.250.250.250.250.25NR
NAFS 2017 Performance Class AW Window – FixedVT20.370.370.370.370.370.370.370.370.370.370.370.370.370.370.370.37
NAFS 2017 Performance Class AW Window – OperableU-factor0.430.430.430.430.430.470.470.430.430.430.430.430.430.430.430.43
NAFS 2017 Performance Class AW Window – OperableRSHGCNR0.24NR0.24NR0.310.310.240.240.240.240.240.240.240.24NR
NAFS 2017 Performance Class AW Window – OperableVT20.370.370.370.370.370.370.370.370.370.370.370.370.370.370.370.37
All Other Windows and Glazed DoorsU-factor0.280.300.280.280.280.300.340.300.300.300.280.300.280.280.300.28
All Other Windows and Glazed DoorsRSHGCNR0.23NR0.23NR0.230.230.230.230.230.230.230.230.230.23NR
Building TypeFeatureCZ 1CZ 2CZ 3CZ 4CZ 5CZ 6CZ 7CZ 8CZ 9CZ 10CZ 11CZ 12CZ 13CZ 14CZ 15CZ 16
SkylightsU-factor0.460.460.460.460.460.460.460.460.460.460.460.460.460.460.460.46
SkylightsSHGCNA0.25NA0.25NA0.250.250.250.250.250.250.250.250.250.25NA
Skylights, Serving Common AreasVT20.490.490.490.490.490.490.490.490.490.490.490.490.490.490.490.49

p.619the area-weighted average U-factor of the floor assembly shall not exceed U-0.071.

p.62014; or

p.622ii. Alterations that add vertical fenestration and skylight area shall meet the total

p.619B. Raised mass floors. A minimum of R-6 insulation, or the area-weighted average U-

p.620d. Buildings with R-2 or greater continuous insulation above or below the roof

p.622fenestration area requirements of Section 170.2(a)3 and the U-factor, RSHGC and VT requirements of Table 180.2-B.

p.619factor of the floor assembly shall not exceed U-0.111.

p.620deck.

p.619(b) Prescriptive approach. The altered component and any newly installed equipment serving

p.619the alteration shall meet the applicable requirements of Sections 110.0 through 110.9 and all applicable requirements of Sections 160.0, 160.1, 160.2(c) and (d), 160.3(a) through 160.3(b)5J, 160.3(b)6, 160.3(c) and 160.5; and

p.621c. In Climate Zones 1 through 4 and 8 through 16, recessed downlight

p.624Footnotes to TABLE 180.2-B:

p.621luminaires in the ceiling shall be covered with insulation to the same depth as the rest of the ceiling. Luminaires not rated for insulation contact must be replaced or fitted with a fireproof cover that allows for insulation to be installed directly over the cover; and

p.6241. Requirements apply to glazed doors included in the Curtainwall/Storefront construction assembly. 2. Minimum VT requirements for fenestration other than Skylights do not apply to multifamily buildings 3 habitable stories or less.

p.6191. Envelope.

p.619A. Roof alterations. Existing roofs being replaced, recovered or recoated of a

p.619multifamily building shall meet the requirements of Section 110.8(i). For roofs with more than 50 percent of the roof area or more than 2,000 square feet of roof, whichever is less, being altered, the requirements of i through iii below apply:

p.620iii. For low-sloped roofs, the area of the roof recover or roof replacement shall be

p.620insulated to R-14 continuous insulation or a U-factor of 0.039 in Climate Zones 1, 2, 4, and 8 through 16.

p.622D. Exterior doors. Alterations that add exterior door area shall meet the U-factor

p.621d. Attic ventilation shall comply with the California Building Code requirements.

p.622requirement of Section 170.2(a)4.p.623

p.619i. Low-sloped roofs in Climate Zones 2, 4, and 6 through 15 shall have a minimum

p.619aged solar reflectance of 0.63 and a minimum thermal emittance of 0.75, or a minimum SRI of 75.

Table 180.2-A Roof/Ceiling Insulation Tradeoff for Low-Sloped Aged Solar Reflectance p.619 Download CSV
Minimum Aged Solar ReflectanceRoof Deck Continuous Insulation R-value (Climate Zones 6-7)Roof Deck Continuous Insulation R- value (Climate Zones 2, 4, 8-15)
0.60216
0.55418
0.50620
0.45822
No requirement1024

p.623SECTION 180.2 – ALTERATIONS

p.624SECTION 180.2 – ALTERATIONS

p.620B. Roof/ceiling insulation.

p.621C. Fenestration alterations other than repair shall meet the requirements of Items i and

p.620i. Attic roof. Vented attics shall meet the following:

p.619ii. Steep-sloped roofs in Climate Zones 4 and 8 through 15 shall have a minimum

p.621ii below:

p.620a. In Climate Zones 1 through 4 and 8 through 16, insulation shall be installed to

p.619aged solar reflectance of 0.20 and a minimum thermal emittance of 0.75, or a minimum SRI of 16.

p.620achieve a weighted U-factor of 0.020 or insulation installed at the ceiling level shall result in an installed thermal resistance of R-49 or greater for the insulation alone; and

p.621i. Fenestration installed to replace existing fenestration of the same total area shall

p.619a. Buildings with ceiling assemblies with a U-factor lower than or equal to 0.025

p.621meet either a or b:

p.619or that are insulated with at least R-38 ceiling insulation in an attic; orp.620

p.621a. The maximum U-factor, RSHGC and VT requirements of Table 180.2-B, orp.622

p.619SECTION 180.2 – ALTERATIONS

p.620SECTION 180.2 – ALTERATIONS

p.621SECTION 180.2 – ALTERATIONS

p.622SECTION 180.2 – ALTERATIONS