SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION (part 4 of 4)

p.155READILY ACCESSIBLE is capable of being reached quickly for operation, repair, or inspection, without requiring climbing or removing obstacles, or resorting to access equipment.

p.156RESNET 380 is the Residential Energy Services Network document titled “Standard for Testing Airtightness of Building Enclosures, Dwelling Unit, and Sleeping Unit Enclosures, Airtightness of Heating and Cooling Air Distribution Systems; and Airflow of Mechanical Ventilation Systems” 2019 (ANSI/RESNET/ICC 380-2019).

p.157SERVICE WATER HEATING is heating of water for sanitary purposes for human occupancy, other than for comfort heating.

p.158SINGLE PACKAGE VERTICAL AIR CONDITIONER (SPVAC) is a type of air-cooled small or large commercial package air- conditioning and heating equipment; factory assembled as a single package having its major components arranged vertically, which is an encased combination of cooling and optional heating components; is intended for exterior mounting on, adjacent interior to, or through an outside wall; and is powered by single or three-phase current. It may contain separate indoor grille, outdoor louvers, various ventilation options, indoor free air discharge, ductwork, wall plenum, or sleeve. Heating components may include electrical resistance, steam, hot water, gas, or no heat but may not include reverse cycle refrigeration as a heating means.

p.159SOLAR ZONE is a section of the roof designated and reserved for the future installation of a solar electric or solar thermal system.

p.160TRIM COMPRESSOR is a compressor that is designated for part-load operation, handling the short term variable trim load of end uses, in addition to the fully loaded base compressors.

p.161VARIABLE AIR VOLUME (VAV) SYSTEM is a space-conditioning system that maintains comfort levels by varying the volume of supply air to the zones served.

p.162SPLIT-HYDRONIC HEAT PUMP WATER HEATER is a HPWH that consists of multiple separate sections. One section houses all the refrigerant components, while one or more additional sections are designated for water storage. These sections are interconnected through a hydronic circuit.

p.155RECOOL is the cooling of air that has been previously heated by space-conditioning equipment or systems serving the same building.

p.157SHADING is the protection from heat gains because of direct solar radiation by permanently attached exterior devices or building elements, interior shading devices, glazing material, or adherent materials.

p.159SOURCE ENERGY is defined as the long run hourly marginal source energy of fossil fuels that are combusted as a result of building energy consumption either directly at the building site or caused to be consumed to meet the electrical demand of the building considering the long-term effects of Commission-projected energy resource procurement. For a given hour, the value in that hour for each forecasted year is averaged to establish a lifetime average source energy.

p.160U-FACTOR is the overall coefficient of thermal transmittance of a fenestration, wall, floor, or roof/ceiling component, in Btu/(hr × ft2 × oF), including air film resistance at both surfaces.

p.161VENDING MACHINE is a machine for vending and dispensing refrigerated or nonrefrigerated food and beverages or general merchandise.

FIGURE 100.1-A—CALIFORNIA CLIMATE ZONES
Text in this figure

#S

#S

#S

#S

#S

#S

#S

#S

#S

#S

16

15

14

13

12

11

10

9

8

7

6

5

4

3

SONOMA

Eureka

Fresno

Alturas

Barstow

San Diego

Sacramento

Bakersfield

San Francisco

South Lake

Tahoe

1

2

14

16

16

50 0 50 100 Miles

CALIFORNIA ENERGY COMMISSION SYSTEMS ASSESMENT & FACILITIES SITING DIVISION CARTOGRAPHY UNIT MARCH 2005

T:\Projects\CEC\Mexico\MX Border.apr VIEW: CZ Building B&W 8.5X11 LAYOUT:CZ Building B&W 8.5X11

S

N

E W

CALIFORNIA BUILDING

CLIMATE ZONES

FIGURE 100.1-A—CALIFORNIA CLIMATE ZONES — p.163
Equation on PDF page 161: M = E + B, where:

Equation text: M = E + B, where:

Needs visual review

p.161

p.155Laundry is a nonhabitable room or space which contains plumbing and electrical connections for a washing machine or clothes dryer.

p.161INTEGRATED HEAT PUMP WATER HEATER is a HPWH that has all components, including fans, storage tanks, pumps, or controls necessary for the device to perform its function contained in a single factory- made assembly.

p.156SELF-UTILIZATION CREDIT is the limited efficiency LSC energy budget compliance credit available for combined PV and battery energy storage systems for single-family, as specified by the Residential ACM Reference Manual, and low-rise multifamily, as specified by the Nonresidential and Multifamily ACM Reference Manual.

p.157A residential building of Occupancy Group R-3 with two or less dwelling units,

p.160USDOE 10 CFR 431 is the regulation issued by Department of Energy and available in the Code of Federal Regulation - Title 10, Chapter II, Subchapter D, Part 431 - Energy Conservation Program for Certain Commercial and Industrial equipment. Relevant testing methodologies are specified in “Subpart E to Part 431 – Uniform test method for the measurement of energy efficiency of commercial packaged boilers.”

p.159TRANSCRITICAL MODE is a system operating condition for a refrigeration system wherein the refrigerant pressure and temperature leaving the compressor is such that the refrigerant is at or above the critical point. Typically used in reference to CO2 refrigeration systems.

p.163FIGURE 100.1-A—CALIFORNIA CLIMATE ZONES

p.157A building of Occupancy Group R-3, other than a multifamily building or hotel/motel building,

p.158SOLAR POOL HEATING SYSTEM is an assembly of components designed to heat water for swimming pools, spas or swimming pool and spa combinations by solar thermal means, excluding pool recirculation components.

p.155Storage building is a nonhabitable detached building used for the storage of tools, garden equipment, or miscellaneous items.

p.163Climate Zones for Residential and Nonresidential Occupancies

p.157A townhouse,

p.156SENSIBLE ENERGY RECOVERY RATIO is a ratio of the change in the dry-bulb temperature of the outdoor air supply to the difference in dry-bulb temperature between the outdoor air and entering exhaust airflow, with no adjustment to account for that portion of the dry-bulb temperature change in the leaving supply airflow that is the result of leakage of entering exhaust airflow rather than heat exchange between the airstreams.p.157

p.161SPLIT-REFRIGERANT HEAT PUMP WATER HEATER is a HPWH which has a single outdoor section and one or more indoor sections connected to the outdoor section via a refrigerant circuit.p.162

p.158SOLAR REFLECTANCE INDEX (SRI) is a measure of the roof's ability to reject solar heat which includes both reflectance and emittance.

p.157A building of Occupancy Group R-3.1, or

p.159TRANSIENT is the occupancy for not more than 30 days of a dwelling unit or sleeping unit.p.160

p.155Utility room is a nonhabitable room or building which contains only HVAC, plumbing, or electrical controls or equipment; and which is not a bathroom, closet, garage, or laundry room.p.156

p.160VAPOR RETARDER CLASS is a measure of the ability of a material or assembly to limit the amount of moisture that passes through the material or assembly meeting Section 202 of the California Building Code.p.161

p.157A building of Occupancy Group U when located on a residential site.p.158

p.158SOLAR SAVINGS FRACTION (SSF) is the fraction of domestic hot water demand provided by a solar water-heating system.p.159

p.155SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.156SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.157SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.158SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.159SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.160SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.161SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.162SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION

p.163SECTION 100.1 – DEFINITIONS AND RULES OF CONSTRUCTION