p.399(d) Alternate Method of Compliance. Any addition, alteration, or repair may comply with the
p.397leaks shall be sealed where such sealing can be made without destruction of existing building components.
p.399requirements of Title 24, Part 6 by meeting the applicable requirements for the entire building.
p.397R. Exterior doors. Alterations that add exterior door area shall meet the U-factor
| Control Specifications | Coded Section | Projects complying with Section 141.0(b)2Ii | Projects complying with Sections 141.0(b)2Iii or 141.0(b)2Iiii |
|---|---|---|---|
| Manual Area Controls | 130.1(a)1 | Required | Required |
| Manual Area Controls | 130.1(a)2 | Required | Required |
| Manual Area Controls | 130.1(a)3 | Only required for new or completely replaced circuits | Only required for new or completely replaced circuits |
| Multilevel Controls | 130.1(b) | Required | Not Required |
| Automatic Shut-Off Controls | 130.1(c)1 | Required | Required |
| Automatic Shut-Off Controls | 130.1(c)2 | Required | Required |
| Automatic Shut-Off Controls | 130.1(c)3 | Required | Required |
| Automatic Shut-Off Controls | 130.1(c)4 | Required | Required |
| Automatic Shut-Off Controls | 130.1(c)5 | Required | Required |
| Automatic Shut-Off Controls | 130.1(c)6 | Required | Required; except for 130.1(c)6D |
| Automatic Shut-Off Controls | 130.1(c)8 | Required | Required |
| Daylight Responsive Controls | 130.1(d) | Required | Not Required |
| Demand Responsive Controls | 110.12(a) and 110.12(c) | Required | Not Required |
p.397requirements of Section 140.3(a)7.
p.3973. Performance approach.
p.397A. The altered envelope, space–conditioning system, lighting and water heating
p.397components, and any newly installed equipment serving the alteration, shall meet the applicable requirements of Sections 110.0 through 110.9, Sections 120.0 through 120.6, and Sections 120.9 through 130.5.
| Altered Component | Standard Design Without Third Party Verification of Existing Conditions Shall be Based On | Standard Design With Third Party Verification of Existing Conditions Shall be Based On |
|---|---|---|
| Roof/Ceiling Insulation, Wall Insulation, and Floor/Soffit Insulation | The requirements of Section 141.0(b)1 and 141.0(b)2Bii. | The requirements of Section 141.0(b)1 and 141.0(b)2Bii. |
| Fenestration The allowed glass area shall be the smaller of the a. or b. below: a. The proposed glass area: or b. The larger of: 1.The existing glass area that remains; or 2.The area allowed in Section 140.3(a)5A. | The U-factor and RSHGC requirements of TABLE 141.0-A. | The existing U-factor and RSHGC levels. |
| Space-Conditioning System Equipment and Ducts | The requirements of Sections 141.0(b)2C, 141.0(b)2Di or Section 141.0(b)2Dii, and Section 141.0(b)2E. | The requirements of Sections 141.0(b)2C, 141.0(b)2Di or Section 141.0(b)2Dii, and Section 141.0(b)2E. |
| Window Film | The U-factor of 0.40 and SHGC value of 0.35. | The existing fenestration in the alteration shall be based on TABLE 110.6-A and Table 110.6-B. |
| Service Water Heating Systems | The requirements of Section 140.5 without solar water heating requirements. | The requirements of Section 140.5 without solar water heating requirements. |
| Roofing Products | The requirements of Section 141.0(b)2B. | The requirements of Section 141.0(b)2B. |
| Lighting System | The requirements of Sections 141.0(b)2F, through 141.0(b)2K. | The requirements of Sections 141.0(b)2F, through 141.0(b)2K. |
| All Other Measures | The proposed efficiency levels. | The proposed efficiency levels. |
p.397B. The standard design for an altered component shall be the higher efficiency of
p.397existing conditions or the requirements of Section 141.0(b)2. For components not being altered, the standard design shall be based on the unaltered existing conditions such that the standard and proposed designs for these components are identical.
p.397C. When the third party verification option is specified, all components proposed for
p.397alteration, for which the additional credit is taken, must be verified. The Executive Director shall determine the qualifications required by the third party inspector.
p.397D. The proposed design shall be based on the actual values of the altered components.
p.397NOTES TO SECTION 141.0(b)3:
p.3971. If an existing component is replaced with a new component, that component is considered an altered component for the purpose of determining the energy budget and shall meet the requirements of Section 141.0(b)3.
p.3972. The standard design assumes the same geometry and orientation as the
p.3973. The “existing efficiency level” modeling rules, including situations where nameplate data is not available, are described in the Nonresidential ACM Reference Manual.
p.398(c) Repairs. Repairs shall not increase the preexisting energy consumption of the repaired
p.398component, system, or equipment.p.399
p.397SECTION 150.0 – MANDATORY FEATURES AND DEVICES